Baumer CleverLevel LBFI Kullanım Talimatları Kılavuzu - Sayfa 12
Ölçüm Cihazları Baumer CleverLevel LBFI için çevrimiçi göz atın veya pdf Kullanım Talimatları Kılavuzu indirin. Baumer CleverLevel LBFI 48 sayfaları. Point level detection – hygienic/industrial level measurement
CleverLevel
Point level detection – hygienic/industrial
9.
Troubleshooting
Fault
LED does not light up
Red LED indicator light
LED flashes red
10. Cleaning, maintenance and repair
Cleaning
Clean, disinfect or sterilize sensor as needed
f
(CIP/SIP).
Maintenance
Regular maintenance is not required.
11. Disposal
Do not dispose of in household
f
waste.
Separate materials and dispose
f
of in compliance with nationally
applicable regulations.
12. Accessories
For adapter and other accessories see www.baumer.com.
13. Technical data
Environmental conditions
Operating temperature
range
Storage temperature range
Ambient humidity
Protection class
Oscillations (sinusoidal)
(EN 60068-2-6)
12 / 48
Level measurement
LBFH/I
®
Cause
Sensor not correctly connected
Short circuit
Unsuitable media characteristics
Device error
-40 ... -85 °C
-40 ... -85 °C
< 98 % RH,
condensing
IP67
IP69K (with
appropriate cable)
1.6 mm p-p
(2 ... 25 Hz),
4 g (25 ...100 Hz),
1 octave / min.
Operating Instructions
Action
Check plug and power supply.
f
Remedy short circuit.
f
Check signal quality with
f
FlexProgrammer.
Dismount and return sensor.
f
Repair
Do not repair the sensor yourself.
Send damaged sensor to Baumer.
f
Features
Repeatability
Hysteresis
Response time
Damping
± 1 mm
± 1 mm
0.04 s
0.1 ... 10.0 s (adjustable)
www.baumer.com