Baumer EXG50 Kullanıcı Kılavuzu - Sayfa 33

Dijital Kamera Baumer EXG50 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Baumer EXG50 42 sayfaları. Gigabit ethernet
Ayrıca Baumer EXG50 için: Kullanıcı Kılavuzu (42 sayfalar)

Baumer EXG50 Kullanıcı Kılavuzu
5.6. Message Channel
The asynchronous message channel is described in the GigE Vision
the possibility of event signaling. There is a timestamp (64 bits) for each announced event, 
which contains the accurate time the event occurred. Each event can be activated and 
deactivated separately.
5.6.1. Event Generation
Event
Gen<i>Cam™
ExposureStart
ExposureEnd
FrameStart
FrameEnd
Line0Rising
Line0Falling
Line1Rising
Line1Falling
Line2Rising
Line2Falling
Line3Rising
Line3Falling
Line4Rising
Line4Falling
Line5Rising
Line5Falling
Vendor-specific
EventError
EventLost
TemperatureExceeded
TriggerReady
TriggerOverlapped
TriggerSkipped
By the individual cameras of the Baumer EXG series the GigE Vision
sage Channel is supported in different degrees.
Description
Exposure started
Exposure ended
Acquisition of a frame started
Acquisition of a frame ended
Rising edge detected on IO-Line 0
Falling edge detected on IO-Line 0
Rising edge detected on IO-Line 1
Falling edge detected on IO-Line 1
Rising edge detected on IO-Line 2
Falling edge detected on IO-Line 2
Rising edge detected on IO-Line 3
Falling edge detected on IO-Line 3
Rising edge detected on IO-Line 4
Falling edge detected on IO-Line 4
Rising edge detected on IO-Line 5
Falling edge detected on IO-Line 5
Error in event handling
Occured event not analyzed
Reference value of temperature exceeded
t
 (see chapter 2.4) elapsed, camera is able to 
notready
process incoming trigger
Overlapped Mode (see chapter 2.4) detected
Camera overtriggered (see chapter 2.4)
 standard and offers 
®
 Mes-
®
33