CAUTION: WHEN INSERTING OR REMOVING CONTACTS, DO NOT SPREAD OR ROTATE
TOOL TIPS.
IV.
Removal:
a.
Slip correct sized tool (with plastic tool, use white end) over wire insulation and slide forward on
wire until tool tip enters rear grommet and comes to a positive stop on contact shoulder. Grip wire,
and simultaneously remove tool, contact and wire. (On occasion, it may be necessary to remove
tool, rotate 90° and reinsert).
b.
Unwired Contacts: Remove sealing plugs. Standard Removal Tools: Using applicable removal
tool, insert and carefully work tool tips over wire well. When tips bottom, contact will release
from internal retention clip. Push contact from connector front face out connector rear with round
ended non-metallic rod. Rod will follow contact. (See Tool Table 3 for applicable removal tool
and correct rod diameter). Unwired Removal Tool (11-10050-XX): Removal procedure is same as
with standard tools with the exception that tool will withdraw contact without pushing from front.
Push plunger to remove contact from tool. (See Tool Table, in catalog, for correct size).