Baumer FLDK 110C1005/S42 Kullanıcı Kılavuzu - Sayfa 10

Kasa Sayacı Baumer FLDK 110C1005/S42 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Baumer FLDK 110C1005/S42 35 sayfaları. Laser copy counter

Baumer FLDK 110C1005/S42 Kullanıcı Kılavuzu
6
Signal sequence
The yellow edge indicator LED lights as long as an edge is located in the beam. The output pulse is issued
at the end of the edge. The dead time begins when the output pulse is issued. During the dead time and
when issuing the pulse, the SCATEC-2 is inactive, i.e. an edge ending during the dead time or the pulse
issue of the previous edge will not initiate an output pulse. Therefore, the next output pulse can only be
issued after the dead time has expired and the output pulse has been issued.
on
off
high
low
on
off
Manual SCATEC-2
Version 2021-09
Running direction
p
t
time
www.baumer.com
yellow edge-LED
output pulse
dead time (period: t )
10
(pulse length: p)
Baumer Electric AG
Frauenfeld, Switzerland