10.3.3 Menu C:
Operational parameters are set in menu C. A detailed description of these parameters is given in section 9
Setting the operational parameters.
Submenus not applicable in the present setting will be skipped in the display!
With the sensor locked, no parameters can be changed while navigation is still possible. The sensor can
be unlocked in menu B. When trying to change a parameter of a locked Scatec, the message "input
locked" will show up as reminder.
The sensor will be locked again if no key is pressed for 30 minutes
Submenu
values
C0:
xx.x ms
Pulse Length
C1:
0 = lead
RunDirection
1 = trail
C2:
0 = off
Fp-Suppress
1 = on
C3:
00 = dyn
Suppr.Mode
01 = sync
02 = fixed
03 = reflx
C4:
xxx
Dead Time %
C5:
x.xx mm
Encodr Resol
C6:
xxx mm
Dead Path mm
C7:
0 = off
Encoder A/B
1 = on
C8:
xxx ms
Dead Time ms
C9:
0 = off
Pulse Delay
1 = on
User manual Scatec-10 / -15
Version 2017-10
Parameters
Comments
Output pulse length in ms
value of output pulse length in milliseconds
Running direction of the copies
leading
trailing
False pulse suppression
no false pulse suppression mode will be activated
a false pulse suppression mode as defined in [C3]
will be activated
False pulse suppression mode
dynamic
synchronous
fixed
retro-reflective foil only
Dead time in percentage
value of dynamic dead time in percentage of the mean
interval between copies
Encoder resolution in mm/pulse
value of encoder resolution in millimeters per
encoder pulse
Dead path in mm
value of synchronized dead path mm
Encoder A/B
only A-channel of encoder is used
A- and B-channels of encoder are used
Dead time in ms
value of fixed dead time in milliseconds
Output pulse delay
output pulse issued immediately after end of the edge
output pulse issued with delay relative to end of the
edge
www.baumer.com