Amphenol PL182X-301-50-G15 Montaj Kılavuzu - Sayfa 5
Kablolar ve konektörler Amphenol PL182X-301-50-G15 için çevrimiçi göz atın veya pdf Montaj Kılavuzu indirin. Amphenol PL182X-301-50-G15 7 sayfaları. 2 pos 50mm2 180d straight plug
HVIL位置需对准
The HVIL position must be aligned
步骤9:建议客户参考下面的测试参数,对线束进行绝缘电阻测试和耐压测试
Step9:Insulation resistance and dielectric withstand voltage tests are obligated to be done according to below test
parameters to guarantee the good electric performance of the whole harness
9-1 绝缘电阻测试
9-1 Insulation Resistance Test
位置
Positions
电缆芯线到壳体
Cable(power) to shell
电缆芯线到高压互锁
Cable(power) to HVIL
高压互锁到壳体
HVIL to shell
9-2 耐压测试
9-2 Dielectric Withstand Voltage Test
位置
Positions
电缆芯线到壳体
Cable(power) to shell
电缆芯线到高压互锁
Cable(power) to HVIL
HVIL to shell
高压互锁到壳体
9-3 测试说明:
警告:建议的电气测试及其参数应根据终端应用要求进行审查,以确保安全性并防止损坏其他部件。提供的参数
是基于PowerLok连接器和其峰值1000VDC额定。提供的测试参数可能超出电缆组件或设备上使用的其他部件/
材料的限制。
9-3 Test note:
caution: Recommended electrical tests and their parameters should be reviewed against end
application requirements to ensure safety and to prevent damage to other components. Parameters
provided are based on the PowerLok connectors and their peak 1000VDC rating. Test parameters
provided may exceed the limit of other components/materials used on the cable assembly or device.
Manual P/N:8P1174 _ Rev.01 20221115
PL182X-301-50-G15 二芯 50mm2 直头插头组装规范 PL182X-301-50-G15 2 POS 50mm2 180D Straight Plug Assembly Manual
① 屏蔽壳组件
Shield shell assembly
测试电压
Test Voltage
1000 VDC
1000 VDC
1000 VDC
测试电压
Test Voltage
5000 VDC
5000 VDC
500 VDC
测试时间(推荐)
Test Time(recommended)
5S
5S
1S
测试时间(推荐)
Test Time(recommended)
10S
10S
1S
将密封圈推到底
Push the seal to the bottom
绝缘电阻
Insulation Resistance
> 500 MΩ
> 500 MΩ
> 100 MΩ
漏电流
Leakage Current
<5mA
<5mA
<5mA
04/05