The operator should remain nearby the equipment through-
out the use to ensure the proper functioning of the system.

6.1 Pumping hot liquids

CAUTION
Excessive temperature-
can cause injury
or severe damage.
When pumping hot liquids, make your you retighten
screws and bolts after starting for the first time in order
to compensate for contraction.

6.2 Pump full of liquid when stopped

WARNING
Hazardous pressure
can cause
personal injury
or property damage.
WARNING
Toxic or hazardous
fluids can cause
serious injury.
If the pump circuit is to be located between valves and/or
a non-return valve, you need to take account of the
variations in temperature that can lead to contraction of
the liquid in the circuit. In this case, you need to provide
some means of compensating for the contraction. A dis-
charge valve may be sufficient. The opening pressure
for this valve should be compatible with the permitted
pressure for the other components in the circuit.
It is also advisable to fit a discharge device to allow the
circuit to be completely emptied for any maintenance work.
In the case of liquids containing particles settling on
shut-down, it is necessary to make sure the consistency
of the deposit will not impede restarting the pump.
NT 1010-I00 03 18 Submerged AM unit on plate e
THE SURFACES OF THE PUMP CAN
BE AT A TEMPERATURE LIABLE TO
CAUSE INJURY OR SEVERE DAMAGE.
FAILURE TO INSTALL ADEQUATELY
SIZED PRESSURE RELIEF VALVE(S)
CAN CAUSE PROPERTY DAMAGE,
PERSONAL INJURY OR DEATH.
IF PUMPING HAZARDOUS OR TOXIC
FLUIDS, THE SYSTEM MUST BE FLUS-
HED PRIOR TO PERFORMING ANY
SERVICE OPERATION.

6. USE

6.3 Starting-up the pump

WARNING
Hazardous pressure
can cause
personal injury
or property damage.
WARNING
Do not operate
without guard
in place.
Before starting the pump, make sure that the following
conditions are met :
• The circuit should be in one of its pumping configu-
rations, with the appropriate valves open, especially
on the intake side.
• For products requiring heating, they must be brought
to their pumping temperature before starting the
pump.

6.4 Running without liquid in the pump

MOUVEX Submerged AM pumps can run without liquid
in the pump for 5 minutes without causing damage, in
particular during pump priming.
6.5 Using of the pump with a valve closed on
the discharge line
The using of the pump with a valve closed on the dis-
charge line implies the liquid is not renewed which gene-
rates a heating up. In consequence, that operating way
must not exceed 3 minutes.

6.6 Shutting down the pump

When shutting down the pump, we recommend waiting
for it to stop completely before closing the valves, espe-
cially the inlet valve.
7/13
FAILURE
TO
RELIEVE
SYSTEM
PRESSURE PRIOR TO PERFORMING
PUMP SERVICE OR MAINTENANCE
CAN CAUSE PERSONAL INJURY OR
PROPERTY DAMAGE.
OPERATION WITHOUT THE SHAFT
PROTECTOR CAN CAUSE SERIOUS
PERSONAL INJURY, MAJOR PROPER-