Dover Hydro systems 595MD Hızlı Başlangıç Kılavuzu
Dağıtıcı Dover Hydro systems 595MD için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Dover Hydro systems 595MD 2 sayfaları. Multi-disk solid dissolver
Troubleshooting Chart:
Problem
Cause
1. System does not operate
a. No water
b. Clogged water inlet strainer
c. Primary float valve failure
2. Discharge from siphon
a. Failed siphon breaker
breaker
3. Float is not turning water
a. Unit not level
flow On/Off
b. Float movement obstructed
4. Solution strength too low
a. Low inlet pressure
b. Inlet tubing kinked
Note: Colder water temperatures result in a decrease in the chemical dissolve rate.
* Hard water may cause build-up of mineral deposits in water valve. Remove deposits by soaking the valve parts in a
deliming solution.
3798 Round Bottom Road, Cincinnati, OH 45244 U.S.A. • Phone: (513) 271-8800 • Fax: (513) 271-0160 •www.hydrosystemsco.com
Solution
a. Open water supply
b. Disconnect inlet water line and clean
strainer
c. Clean*, rebuild with parts kit or replace.
a. Repair or replace siphon breaker
a. Make sure unit is level - float hangs free
b. Make sure float is not obstructed
a. Adjust inlet pressure higher using
reguator 30-40psi is recommended
(Turn pressure adjustment screw
clockwise to increase pressure)
Make sure tubing is not kinked
b. Adjust tubing to prevent kinking
10094917
Rev. C 4/15
Multi-Disk Solid Dissolver
THANK YOU FOR YOUR INTEREST IN OUR PRODUCTS
Please use this equipment carefully and observe all warnings andcautions.
*************************************************** NOTE ********************************************
protective clothing and eyewear when dispensing chemicals or other materials or when working in the vicinity of all chemicals,
WEAR
filling or emptying equipment, or changing metering tips.
observe safety and handling instructions of the chemical manufacturer.
direct discharge away from you or other persons or into approved containers.
ALWAYS
install solid dissolver in an area with a floor drain nearby, and connect overflow port with hose to drain.
dispense cleaners and chemicals in accordance with manufacturer's instructions. Exercise CAUTION when maintaining your
equipment.
reassemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position.
KEEP
equipment clean to maintain proper operation.
UNIT SPECIFICATIONS:
Weight: -- 15lb. Dry
-- 45lb. With four chemical disks and full solution reservoir
Dimensions: -- 14" W X 29" H X 10" D
Installation and Operation:
1. Drill holes for the four wall
2. Remove top screw from
anchors with a (9/32") drill,
black access panel to install
using the mounting board as
float.
a template. Make sure the
board is level.
6. Install the outlet ball valve
5. Connect water supply line
to the inlet ball valve push-in
and bushing using thread
sealant.
fitting.
Package Should Contain:
1. Dissolution Board
595 MD
2. Float
3. S-hook
4. Siphon Breaker-Installed
5. Outlet Ball Valve
6. Mounting Kit
7. Overflow Fitting
8. Instruction Manual
3. Install the float on the
S-hook inside the board.
Verify float operation is not
obstructed.
7. Connect the outlet supply
line to the outlet ball valve.
Continued
→