Follett HCC1010A Kullanıcı Kılavuzu - Sayfa 14

Buz Yapıcı Follett HCC1010A için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Follett HCC1010A 16 sayfaları. Ice machines (self-contained) 50 hz and 60 hz

Follett HCC1010A Kullanıcı Kılavuzu
Ice capacity test
Ice machine production capacity can only be determined by weighing ice produced in a specific time period.
1. Replace all panels on ice machine.
2. Run ice machine for at least 15 minutes.
3. Weigh and record weight of container used to catch ice.
4. Catch ice for 15 or 20 minutes.
5. Weigh harvested ice and record total weight.
6. Subtract weight of container from total weight.
7. Convert fractions of pounds to decimal equivalents (ex. 6 lbs 8oz = 6.5 lbs).
8. Calculate production using following formula:
1440 min. x wt. of ice produced
Total test time in minutes
9. Calculated amount per 24 hours should be checked against rated capacity for same ambient and water
temperatures in Ice Production Tables.
14
=
Production capacity/24 hr.
Horizon Elite 1010/1410 Self-Contained (50 Hz and 60 Hz)