Follett HCC1010AHT Hızlı Başlangıç Kılavuzu - Sayfa 5
Buz Yapıcı Follett HCC1010AHT için çevrimiçi göz atın veya pdf Hızlı Başlangıç Kılavuzu indirin. Follett HCC1010AHT 8 sayfaları. Self-contained chewblet ice machine
Ayrıca Follett HCC1010AHT için: Manuel (8 sayfalar)
3 – Undercounter/in-cabinet mounting and ventilation
Using Follett supplied grilles
Horizon Elite ice machines can be installed undercounter/in‑cabinet to fill bins or dispensers using RIDE technology. Care must be
taken to ensure proper cabinet venting to avoid recirculation of hot air. Improper venting can cause ice machine outages.
Supplied
grilles
exhaust
cabinet door
supplied intake grille
Important specifier notes for using Follett supplied grilles
1. The supplied exhaust grille must be located at least 18.00" (45.7 cm)
from the supplied air intake grille (exhaust air must not recirculate
with intake air).
2. Cabinet interior must be open to allow for unrestricted exhaust
air flow.
3. Ice transport tube needs minimum 1/4" per foot (2 cm per meter)
pitch toward ice machine and should be secured to prevent dips and
traps from forming.
Self-contained 1010, 1410 series ice machine
Horizon Elite
ice machine
18.00" (45.7 cm)
minimum
25.25" (64.1) cm)
23.50"
(59.69 cm)
Cabinet door
air in
minimum
must mate directly
to air intake gasket
air intake gasket
door & gasket
must mate
directly
locating
cutout
2.00"
(5.08 cm)
cutout for supplied air intake grille
24.00"W x 16.00"H (61.0 cm x 40.6 cm)
minimum
r
electric
water
drain
12.00" (30.5 cm) minimum
between ice machine
and dispenser
Horizon Elite ice machine
2.25" (5.72 cm)
cutout
bottom of ice machine
side of ice machine
4. Cabinet door must mate directly to air intake gasket.
5. Cabinet interior must provide a minimum clear space of 23.50"
(59.7 cm) high by 25.25" (64.1 cm) deep.
6. Cutout for supplied grilles must meet minimum size requirements
shown above.
7. Utilities should be conveniently located as shown.
Ice transport tube
minimum 1/4" per foot
(2 cm per meter)
pitch toward ice machine
secure to prevent dips
and traps from forming
see dispenser
specification
sheet for
installation
requirements
Completed installation with
gasket and door in place –
Side view
25.25" (64.1 cm) min.
Front
23.50"
(59.7 cm)
minimum
5
Form# 7030