Dimensional drawing
Specification, condenser unit
W1 Width
D1 Depth
H1 Height
Electrical
Operating power
Minimum circuit ampacity
Maximum overcurrent protection
Outdoor condensing unit operating limits
(air temperature)
Maximum refrigerant line run length
Maximum line rise above evaporator
Evaporator mounting above condenser
Maximum refrigeration line drop without oil trap
Refrigerant charge
Approximate ship weight
Approximate net weight
NOTE:
1. The entire liquid line should be insulated separately from the suction line.
Remote 1010, 1410 series ice machine
D1
W1
Horizon Elite 1010 series
36.25" (91.4 cm) – all models
25.50" (64.8 cm) – all models
26.10" (66.3 cm) – all models
single phase – 208-230/60/1
three phase – 208-230/60/3
single phase – 2.4 kW
three phase – 2.2 kW
single phase – 10.7 A
three phase – 9.9 A
single phase – 15 A
three phase – 15 A
min -20 F (-29 C)
max 120 F (49 C)
100' (30.5 m)
35' (10.7 m)
15' (4.6 m)
15' (4.6 m)
14.5 lb required at installation
260 lb (136 kg)
250 lb (114 kg)
H1
Horizon Elite 1410 series
36.25" (90.1 cm) – all models
25.50" (64.8 cm) – all models
26.10" (66.3 cm) – all models
single phase – 208-230/60/1
three phase – 200-230/60/3
single phase – 4.2 kW
three phase – 3.1 kW
single phase – 19.3 A
three phase – 14.2 A
single phase – 30 A
three phase –25 A
min -20 F (-29 C)
max 120 F (49 C)
100' (30.5 m)
35' (10.7 m)
15' (4.6 m)
15' (4.6 m)
14.5 lb required at installation
270 lb (145 kg)
260 lb (136 kg)
3