Specifications

Electrical
Separate circuit and equipment ground required.
Evaporator unit
Standard electrical: 115/60/1
Maximum fuse: 15A
Amperage: 5A
Condensing unit
Electrical
Max Circuit HVACR breaker size
Min Circuit Ampacity
Evaporator plumbing
§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required.
§ Water shut-off recommended within 10 feet (3 m).
§ Follett recommends installation of Follett water filter system (part# 00130286) in ice machine inlet water line.
Flush drain plumbing
§ 3/4" MPT flush drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
2 ft. x 1" OD
silicone tubing
(6,4 mm per 0,3 m)
Horizon Elite 1010/1410 Ice Machines (Remote Condensing)
1010 Single-Phase
208-230V, 60Hz
15A
10.7A
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1/4" per foot
1'
1010 3-Phase
1410 Single-Phase
208-230V, 60Hz
15A
9.9A
1" PVC Drain
1410 3-Phase
208-230V, 60Hz
208-230V, 60Hz
30A
19.3A
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1" Stand pipe/Drain
25A
14.2A
3