Follett Horizon Elite Micro Chewblet 1010 Series Kurulum Talimatları Kılavuzu - Sayfa 10

Buz Yapıcı Follett Horizon Elite Micro Chewblet 1010 Series için çevrimiçi göz atın veya pdf Kurulum Talimatları Kılavuzu indirin. Follett Horizon Elite Micro Chewblet 1010 Series 17 sayfaları. For drop-ins
Ayrıca Follett Horizon Elite Micro Chewblet 1010 Series için: Kurulum Talimatları Kılavuzu (16 sayfalar)

Follett Horizon Elite Micro Chewblet 1010 Series Kurulum Talimatları Kılavuzu
Connect utilities to docking assembly.
6.1
Water and drain
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
• Rough-in ice machine potable water
supply
.
3/8" push-in connection will be made at
shut-off valve inside machine
• Remove access panel if necessary
• Connect the silicone tubing to the ice
machine 3/4" drain barb
• Assemble the 3/4" barb x 3/4" FPT to the
3/4" MPT x 1" slip. Connect the other end
of the silicone tubing to the 3/4" barb
• Connect the 1" slip fitting to the 1" stand
pipe/drain
.
Note: Minimum 8" radius on silicone
drain line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4 mm/0,3 m).
• Apply Petrol-gel to barbed drain fitting
• Replace access panel.
10
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
.
.
.

External connections

6.2
Refrigerant
• Braze supplied quick-connect lines onto
stub-ins
remote condensing
.
DROP-IN • RIDE Technology
6