Follett Symphony Plus 12CI425A Kurulum Kılavuzu - Sayfa 12

Su Sebili Follett Symphony Plus 12CI425A için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Follett Symphony Plus 12CI425A 17 sayfaları. Ice and water dispensers

Follett Symphony Plus 12CI425A Kurulum Kılavuzu

Electrical system

ATTENTION!
To prevent circuit breaker overload, wait 15 minutes before restarting this unit. This allows the
compressor to equalize and the evaporator to thaw.
Normal control board operation
The PC board indicator lights provide all the information necessary to determine the machine's status. Green
indicator lights generally represent "go" or normal operation; Yellow indicators represent normal off conditions; Red
indicators generally represent alarm conditions, some of which will lock the machine off.
A flashing green light labeled POWER indicates power to the machine. All other normal operation status indicators
are covered as follows:
Ice machine disposition
Legend:
ON
1.
Ice machine is making ice.
2. Ice machine is not making ice.
Control board DIP switch settings

OFF POSITION

OFF
Sleep cycle
disabled
Not used
Sleep cycle
dispense duration
20 min. time delay
Flush disabled
Maint. timer ON
12
12CI425A, 12HI425A
Operating conditions
OFF
ON or OFF
1.
2. Normal time delay. When the bin fills with ice, the LOW BIN
ON POSITION
ON
Sleep cycle
enabled
Not used
Sleep cycle
dispense duration
60 min. time delay
Flush enabled
Maint. timer OFF
FLASHING
Normal running.
light goes out momentarily and the refrigeration and auger
drive systems immediately shut down. (Note: The fan motor
will continue to run for 10 minutes to cool condenser) The TIME
DELAY light comes on, initiating the time delay period. When
the time delay expires, the machine will restart provided that the
LOW BIN light is on.
Sleep cycle dispense duration
OFF
ON
35 s
5 s
15 s
60 s