Follett EREF4-00000 Kurulum, Çalıştırma ve Servis Kılavuzu - Sayfa 3

Buzdolabı Follett EREF4-00000 için çevrimiçi göz atın veya pdf Kurulum, Çalıştırma ve Servis Kılavuzu indirin. Follett EREF4-00000 20 sayfaları. Undercounter refrigerator

Follett EREF4-00000 Kurulum, Çalıştırma ve Servis Kılavuzu

Welcome to Follett

Follett equipment enjoys a well-deserved reputation for excellent performance, long-term reliability and outstanding after-
the-sale support. To ensure that this product delivers that same degree of service, we ask that you take a moment to review
this manual before beginning the installation. Should you have any questions or require technical help at any point, please
call our technical service group at +48 58 785-6140.

Before you Begin

After uncrating and removing all packing material, inspect the equipment for concealed shipping damage. If damage is found,
notify the shipper immediately and contact Follett Corporation so that we can help in the filing of a claim, if necessary.
Check your paperwork to determine which item number you have. Follett item numbers are designed to provide
information about the type of refrigerator you are receiving. Following is an explanation of the different item numbers.
Model Number
EREF

Specifications

Series Specifications

794 mm height, 603 mm width, 654 mm depth (702 mm with handle)
Fits below 850 mm high, ADA-compatible counter
103.0 L capacity
Climate Class
Climate class: 5

Electrical Specifications

230V, 50 Hz, 1 phase
Full load: 4.0A
Minimum circuit ampacity: 6A
Maximum size of branch circuit overcurrent device: 16A

Refrigeration Specifications

Refrigerant – R404A
Charge size – 290 g
Maximum design pressures:
High side – 375/25.8 psi/bars
Low side – 174/12.0 psi/bars
Installation Specifications
Ambient temperature must not exceed 43 C (109.4 F).
The front louvered panel must be kept free of any cabinet trim or obstructions to ensure proper ventilation of the
refrigeration system.
Important cautions
• When power cord is connected to mains, high voltage is still present on the refrigerator's electrical
components; regardless the panel switch is in the OFF position!
• Equipment must be wired according to local and NEC/IEC codes.
• Always disconnect power before servicing refrigerator.
• Servicing is allowed only by qualified personnel.
• Refer to the wiring diagram prior to installation.
Item Number
EREF4-00000
EREF4-KP0000
Keypad
Stackable/Use with Pedestal
X
X
X
EREF Refrigerator
3