Installation
Observe all safety and warning information (see the
X
X
Safety section).
Follow the enclosed manufacturer's information.
X
X
INFO
The product must not be installed above
cooling devices, dishwashers, stoves, ovens,
washing machines or driers.
4.1
Checking the scope of delivery
Name
Recirculation unit 1 (UUE1)
Operating and installation instructions
Tab. 4.1
Scope of delivery
Check the scope of delivery for damage and make sure
X
X
it is complete.
If there are any missing or damaged parts, please
X
X
notify BORA After Sales Service.
Do not under any circumstances install parts which are
X
X
damaged.
Dispose of transport packaging in the proper manner
X
X
(see the Decommissioning and Disposal section).
4.2
Assembly instructions
Keep the airflow channels as short as possible.
Q
Q
Do not install the recirculation unit in floor units or
Q
Q
bodies with no separation from the doors or drawers
as the positive pressure could cause these to open of
their own accord.
The drawers, back panels and shelves in the floor unit
Q
Q
must be removable for maintenance and cleaning
purposes.
If the recirculation unit is installed in an adjacent room,
Q
Q
air recirculation must occur in the room in which the
vapour extraction system is installed so as not to
generate any low pressure.
4.3
Installing the recirculation unit
INFO
A return flow aperture of > 500 cm
plinth area must be provided for recirculation.
INFO
The air duct diameter must be no less than
150 mm (176 cm
INFO
With an air duct length of 50 cm, no corner or
bend should be installed before the fan module
(motor).
www.bora.com
Quantity
1
1
in the
2
).
2
INFO
Install straight duct pieces with a length of at
least 50 cm between the corners or bends.
4.3.1 Installing the recirculation unit
Compressed tape is installed on the recirculation
Q
Q
unit's internal connection to enable this to be securely
attached.
Connect the duct with the recirculation unit's ducting.
X
X
Evenly push the recirculation unit onto the ducting.
X
X
Remove the protective film from the Velcro fastener on
X
X
the outer side of the recirculation unit.
Use the Velcro fastener to prevent the recirculation
X
X
unit from slipping.
Stick the connections for the ducting sections to the
X
X
housing with an air tight join
UDB25 sealing tape can also be used for air-tight
Q
Q
installation (not included in the scope of delivery). The
UDB25 sealing tape (Universal accessory UDB25) can
be obtained from your BORA distributor.
4.3.2 Replacing the Universal recirculation
unit
Switch off the cooktop extractor as shown in the BORA
cooktop extractor operating instructions.
Open the revision option to access you appliance.
X
X
Loosen the appliance with the angle brackets.
X
X
Remove the appliance from the ducting.
X
X
Clean the ducting with a soft cloth and detergent or
X
X
water.
Install the replacement appliance as described in the
X
X
Installation section.
Check that all the duct connections are tight and
X
X
secure.
Check that the appliance functions correctly.
X
X
Do this by putting the cooktop extractor into operation
X
X
as shown in the BORA cooktop extractor operating
instructions.
Seal any possible leakages.
X
X
Re-check the tightness of the connections.
X
X
Seal the revision option.
X
X
Properly dispose of the used filter.
X
X
4.4
Handover to user
Once installation is complete:
Explain the main functions to the user.
X
X
Explain all safety-related aspects of operation and
X
X
handling to the user.
Provide the user with the accessories and the
X
X
operating and installation instructions for safe storage.