DPI Xcel 7QP-12F950P25-C01 Manuel - Sayfa 8
Akü Şarj Cihazı DPI Xcel 7QP-12F950P25-C01 için çevrimiçi göz atın veya pdf Manuel indirin. DPI Xcel 7QP-12F950P25-C01 15 sayfaları. 10-channel/bank 6,8,12v battery charger
'AH' is an abbreviation for 'Ampere-Hour' and denotes the capacity rating of
the battery. For example, a battery rating of 32AH stores more energy and
has a higher energy capacity than an 18AH battery. These AH capacities
also help establish charge safety timer values, explained further in the next
section.
Lead Acid batteries are typically 2V per cell.
12V Lead Acid batteries contain 6cells
-
8V Lead Acid batteries contain 4cells
-
6V Lead Acid batteries contain 3cells
-
*NOTE: The Absorption Value is listed as Volts Per Cell and is one of the
most important parameters pertaining to that charge algorithm. Different
batteries have differing number of cells – multiply the number of cells times
the 'Volts-Per-Cell' value to obtain the voltage the charger will regulate during
the Absorption Charge Stage. Two Examples are shown:
MODE-1
MODE-25 4cell Lithium – 'Green' has 4 cells 3.650V x 4
6. LED, LCD Display And Menu Button
LED Charge Channel Indicators:
Yellow Charge LED – illuminates continuously or flashes while charging
Green Charged LED – illuminates continuously when charge completes
Yellow / Green Alternate Flash – Charge error occurred on that channel
If the Yellow/Green LEDs of a particular Channel, flash Alternately, then
charging on that Channel only, has terminated due to a Charge Error
Condition. Refer to the Charge Error Table for a description of the possible
causes of failure. Resetting a Channel Error is easy - disconnect / connect
DC Cable to battery, and/or refer to charge error table.
MENU SELECT BUTTON:
Depress and hold depressed for approximately 3seconds or more and then
release to enter into the Menu Selection items.
If no further MENU Button depress/release actions are done, a timeout of
approximately 10seconds automatically exits the Menu Selection.
While a Menu Selection is shown, depress the MENU Button for a minimum
of 3 seconds to select that menu item shown. For example, the first Menu
Item displayed is the 'CHARGING MODE'. To select this menu item, depress
and hold depressed the MENU Button until the CHARGING MODE menu
item enters. This menu item then displays the active and current Charge
Mode and Battery Type information.
The SOFTWARE VERSION Menu Item displays information concerning the
product's firmware. Enter this menu item the same way as you would the
CHARGING MODE.
When not in the Menu Selection Mode, each depress/release operation of
the MENU Button will advance the channel display to display the charging
status and Amps/Volts readings of that display. If channel displayed is
Channel-10, the LCD display will roll over to display Channel-1.
12V General Lead Acid has 6 Cells 2.400V x 6 Absorption = 14.40Vdc
8
Absorption = 14.60Vdc