fingerprint reader window. The LCD shows "ID No. Verified" followed by Time Delay.
For example:
Time Delay is set 20 minutes and Time Window 10 minutes. After an enrolled code is
verified successfully, the LCD shows:
8.6V
12/11:34
Time Delay
20:00
The entry pad will start counting down. The LCD screen flashes every 15 seconds for
remaining time. When Time Delay finishes counting down, two beeps will sound and the
LCD screen will show:
8.6V
12/11:34
TM Window
10:00
The entry pad will start counting down again. The LCD screen flashes every 15 seconds
for remaining time .
During the 10 minute Time Window, user can verify an enrolled code or fingerprint again
to unlock the entry pad with the LCD showing:
8.6V
12/11:34
Lock Open
06 sec
Note: When the entry pad starts its Time Delay process, user can operate the entry
pad normally, but the actuator will not be unlocked even if the verification is
successful.
If no enrolled code or fingerprint is verified successfully during Time Window
period, the actuator will be locked to the end and the LCD will show:
8.6V
12/11:34
TM Window
End
Note: If the Time Window is set 0 minute, there is no need to verify second time. When
Time Delay ends, the actuator will be unlocked automatically
If Time Delay is set 0 minute, Time Window will automatically be 0 minute After
successful verification, the actuator will be unlocked automatically.