Bosch Ascenta SHE4AM12U Onarım Talimatı - Sayfa 26

Bulaşık Makinesi Bosch Ascenta SHE4AM12U için çevrimiçi göz atın veya pdf Onarım Talimatı indirin. Bosch Ascenta SHE4AM12U 27 sayfaları.
Ayrıca Bosch Ascenta SHE4AM12U için: Onarım Talimatları (50 sayfalar)

Bosch Ascenta SHE4AM12U Onarım Talimatı
6.3

Troubleshooting

6.3.1
Protection of heater if there's no water
Two NTC's protect the heater. Both NTC's are checked by the
control – if they overheat, the control shuts down the dishwasher
(E:08 fault code). The dishwasher shuts down if only one NTC
returns a signal (E:12 fault code) or if they show different values
(E:11 fault code).
6.3.2
Heat pump terminal measurements
There are two connectors, 7-pin and 3-pin.
6.3.2.1 7-pin connector (heater / NTC's / pump ground)
The 7-pin connector connects to the heat pump heater, NTC's
and ground.
Pump
Motor
5
7
6
4
3
2
6.3.2.2 3-pin connector (3-pole BLDC motor)
The 3-pin connector connects to the 3-pole BLDC motor. The
power control module controls motor speed, starting and
stopping.
702_58300000130262_ara_en_b
7 – NTC 1
6 – NTC common
5 – NTC 2
4 – Line (hot)
3 – X1 (heater common)
2 – Neutral
1 – Ground
1
6.3.3
Drain pump
There is a single 3-pin connector, connecting to the 3-pole BLDC
pump motor.
Resistances as follows:
1 – 2: 89.6 Ω (@ 68 ºF)
2 – 3: 89.6 Ω (@ 68 ºF)
3 – 1: 89.6 Ω (@ 68 ºF)
Page 26 of 27