Faults & troubleshooting
Fault
Ring saw does not start
Ring saw starts then stops
Ring blade not rotating
Ring blade revolved too slowly
Ring blade disengages
Ring blade twisted
Diamond segments broken off
No water supply to ring saw
Blade is loose
EMDS110V | EMDS220V
Possible cause
Faulty main cable
Faulty power supply
Electric motor or motor
components faulty
Fuse on power supply
trips
Ring blade not located
correctly on the profiled
drive roller
Drive roller dirty
Roller pre-tension device
not engaged
Drive rollers worn
Roller bearing defective
Insufficient motor power
Roller pre-tension device
not engaged
Roller distance too large
Drive rollers worn out
Ring blade damaged
Roller pre-tension device
not engaged
Not enough water cooling
your blade
Twisted ring blade
Hard resistance in work
piece
Brazing or welding of
segments not professional
standard
Water line blocked
Water faucet on feed line
is closed
Insufficient water pressure
Re-set front cover
ACG Saws & Tools of Canada Inc.
Solution
Contact ACG Saws for replacement
Check your power supply
Contact ACG Saws for replacement
parts or repair service
Fuse is weak or needs replacement,
change power supply
Reinstall ring blade correctly on the
drive roller
Clean drive rollers
Check roller pre-tension device and
spring
Change drive rollers
Change roller bearings
Check motor
Check roller pre-tension device and
spring
Check roller pre-tension device and
spring
Change drive rollers
Change ring blade
Check roller pre-tension device and
spring
Check water cooling and change ring
blade
Change ring blade
Change ring blade
Change ring blade
Clean or change the water lines
Open the water faucet
Check and increase water supply
Loosen mud guard and blade guard.
Then push front cover in tight. Tighten
guards
8 | P a g e