DRAKE SDE24 Kullanım Kılavuzu - Sayfa 13

Modülatör DRAKE SDE24 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. DRAKE SDE24 19 sayfaları. Hybrid qam modulator; digital tuner and demodulator module; encoder module; asi input module
Ayrıca DRAKE SDE24 için: Kullanım Kılavuzu (18 sayfalar)

DRAKE SDE24 Kullanım Kılavuzu
Operating Instructions - From Drake Digital Headend
Control Program
1) Confirm that all connections to the MEQ1000 and its
installed encoder modules have been made as described
previously. Connect a serial cable from the RS232 IN
connector on the MEQ1000 to the serial port on the PC. (This
discussion assumes that the Headend Control Program has
already been installed on the PC as per the instructions
supplied with the software.)
2) Activate the software. You
should see a screen similar to
FIGURE 1 at right.
3) Click on the 'Setup New
Headend' button. This will
bring up the screen shown in
FIGURE 2. Type in the name
of the headend in the
'HeadEnd Name' field. In this
case we have typed in
MEQ1000. Then select the
'PC Baudrate' and 'Using
Port'. If you intend to use a
modem instead of a direct
connection, make that
selection using the 'Connect
via:' radio buttons, and type in
the phone number of the
desired modem in the 'Number
to dial' window. Then click
'OK'.
4) You will be presented with
a screen similar to the one
shown on FIGURE 3. Click on
the MEQ1000 tab, and click on the box representing the
MEQ1000 unit ID of the unit you are programming. In this
example we selected Unit ID #1. Then click on the 'View Edit'
button.
Select MEQ1000 Unit ID
View/Edit Button
FIGURE 3
This will bring up the screen shown in FIGURE 4. Click on
the Transcoder box and select the transcoder number you
wish to program. In this case we have selected Transcoder
1. Then select 'Input A' and select the number of the encoder
Operating Instructions (From Drake
Digital Headend Control Program)
FIGURE 1
FIGURE 2
MEQ1000 Tab
you choose to
program. In this
case, 'Input A'
contains an SDE24
which contains two
encoders. Select
radio button '1' and
program each
parameter to the
desired value.
Select radio button
2 and set each
parameter to the desired value. Select in turn, 'Input B', 'Mux
Setup' and 'Output' and set each parameter as described
previously. Note that if the value of the parameter selected in
the left column differs from the value of that parameter in the
right column, that value will appear in red.
6) Click on the 'Set Major/Minor Channel Numbers' button.
You will be presented with a screen shown in FIGURE 5.
7) This screen allows
the user to reasign
MPEG numbers as
well as new major and
minor channel
numbers.
8) Once the selec-
tions have been
made, click on the
'Download to
MEQ1000' button.
This will transfer all
selections on this
screen as well as all
selections made on
the previous screens
to the MEQ1000 and
its installed modules.
Close this screen by clicking on the 'X' in the upper right
hand corner of the screen.
9) You will note that all of the items in the right hand columns
in the 'Input A', 'Input B', 'Mux Setup' and 'Output Encoders',
screens are now black and agree with the selections made in
the left hand columns.
10) Additional information on the operation of the Drake
Digital Headend Control Program can be found in the
instructions included on the program CD.
13
FIGURE 4
FIGURE 5