DOOR
LOCK
START KILL
DOOR
OUTPUT
OPEN
PIN
B+
ACC
SIREN OUTPU
HARNESS A'SSY AND COLOR CODE
1. PIN14 : RED - +12V
3. PIN12 : GREEN – DOOR LOCK
5. PIN10 : VIOLET – START IN
7. PIN8 : WHITE – SHOCK SENSOR
9. PIN6 : LIGHT BLUE – ARMED INPUT
11. PIN4 : YELLOW/BLACK – START KILL
13. PIN2: NONE
2. FCC Information
Caution : Any changes or modifications in construction of this device which are not expressly
approved by the party responsible for compliance could void the user's authority to operate
the equipment.
3. FCC Label Information
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1)This device may not cause harmful interference, and
(2)this device must accept any interference received,
including interference that may cause undesired operation.
STAND ALONE OPERATION
DOOR LOCK INPUT
DOOR UNLOCK INPUT
DOOR
UNLOCK
DOOR PIN INPUT
TRUNK INPUT
TRUNK
OPEN
B+
ENGINE
ON
START INPUT
(ARMED INPUT)
+12V(B+)
MAIN
2. PIN13 : BROWN – ACC2
4. PIN11 : BLUE – DOOR UNLOCK
6. PIN9 : GRAY – TRUNK
8. PIN7 : YELLOW – DOOR INPUT
10. PIN5 : PINK – HORN OUT
12. PIN3 : BLACK - GND
14. PIN1 : NONE
ANT
B+
TX
MODULE
(KEY)