2 Disengage closure from extrusion inside the case. Rotate closure as
shown in Fig. 4 and remove, holding it so the closure remains in this posi-
tion and does not bow before placing it on a flat surface.
Bottom Access Panel Door
Caution: Beware of pinch points at ends of closure
Access XL case as seen from below
Accessory Access ACXLE & ACXLV Roller Installation
Please note: When ordering a motor with built-in Low Voltage Controller, if the
case ships separate from the "guts," the case includes the 762cm cable and
special low voltage switch.
1 Remove the bottom access panel (see "Bottom Access Panel Installation/
Removal" section above).
2 The motor end mounting bracket has a metal bracket with snap ring for
accepting motor head. The idler end mounting bracket has spherical ball
bearings for accepting the idler pin. Both brackets have four set screws that
will be used to tighten the brackets in place inside the case. Back out the
four set screws in bracket until they are flush with top side of bracket, then
remove the roller assembly from the shipping brackets, placing the roller
assembly on a flat, clean surface (see Fig. 5).
Shipping Brackets
Motor End (Series V shown)
Please Note: Do not lose the snap ring and screw from the motorized
end, or the eight nylon washers, spring lock washer, fender washer and
machine screw from the idler end. They are required for re-attaching the
roller assembly to the brackets inside the case.
3 To engage the motor end bracket flange above the two channels in the top
of the screen housing, rotate the bracket approximately 45° counter-
clockwise to allow the top surface of the motor bracket to rest flat against
the top inside of the housing. Rotating the bracket clockwise until it is
engaged with the mounting channel, slide it along the length of the housing
against the electrical junction box. Note: Set screw collar side of the bracket
must point toward the center of the case.
Caution: Do not allow the bracket to rotate and fall out of the channel!
4 Tighten all four set screws.
OR
Figure 4
Bottom flange of
Access housing
Carriage
Bolt
Idler End (Series E shown)
Figure 5
www.draperinc.com
5 Replace the eight Nylon Washers into the idler end of the roller assembly.
6 Loosen the carriage bolts which attach the flange-mounted bearing to the
idler end bracket just enough to allow the bushing some limited movement,
which will help when installing the roller assembly.
7 Rotate the bracket into the mounting channel located in the case top (when
mounting the roller assembly into the case). Both the bracket flange and set
screw collar side of the bearing must point toward the gudgeon assembly.
8 Raise the roller/fabric assembly up into the screen housing and engage the
head of the motor completely into the motor mounting bracket, making sure
the snap ring engages with the motor and that the limit switch adjusting
knobs are visible from the bottom of the screen housing (see Fig. 6).
Please note: Maximum torque for
tightening screw is 6.77 Nm.
Figure 6
Caution: When placing the roller assembly into the case, be sure
motor is fully re-seated in the bracket, and secure it carefully with the
motor retaining spring and screw. Limit adjustment screws should be
facing down to allow access to them.
Caution: Due to the weight of the roller assembly, this step requires at
least two people to perform safely.
9 While supporting the idler end of the roller, slide the idler end mounting
bracket toward the roller. Slide the bearing over the end of the shaft.
Caution: Do not allow bracket to rotate and fall out of channel!
Align the bracket into the housing and tighten all four of the set screws.
Lock the roller assembly into place on the mounting bracket with the fender
washer, spring lock washer and machine screw (see Fig. 7).
10 Re-tighten the carriage bolts in the Idler-end Bracket Assembly so that the
flange-mounted bearing is locked in place (see Fig. 5).
Idler End
Roller Bracket
Setscrews
8 Nylon
Washers
Roller
Gudgeon
Assembly
11 Tighten the two set screws in the bearing collar.
12 Connect electrical plug from motor to mating socket on junction box.
13 Reinstall the bottom access panel as previously described (see Figs 3 & 4).
Motorized Roller/Fabric Removal
Reverse the instructions above "Motorized Roller/Fabric Installation" for
removal of the unit.
Operation
When screen is first operated, be cautious! Cycle unit down and up several
times to confirm satisfactory operation.
220V SINGLE STATION CONTROL—3-position UP-OFF-DOWN switch
permits operation to be stopped at any point. Factory adjusted limit switches
automatically stop screen when fully down or fully up.
220V MULTIPLE STATION CONTROL—(Not CE Approved) Switches are
similar in appearance to 220V Single Station Control. Screen stops when
switch is released and may be restarted in either direction. Factory adjusted
limit switches stop screen automatically when fully down or fully up.
24V CONTROL—Three-button UP-STOP-DOWN switches stop at any
point desired, operate in any sequence. Factory adjusted limit switches
automatically stop screen when fully down or fully up. Installer should
incorporate an all-pole disconnect in the fixed wiring.
220V & 12V VIDEO INTERfACE CONTROL—(Not CE Approved) Allows
screen to be controlled by a trigger signal—when the signal comes on, the
screen descends automatically. Two versions: Model VIC220 integrates screen
operation with a Draper video projector lift or a video projector or tuner with a
220V switched outlet. Model VIC12 interfaces with a 12V switched outlet. Both
(765) 987-7999
page 2 of 5
Setscrews
Fender
Bearing
Washer
Collar
Machine
Screw
Spring
Lock
Washer
Carriage
Bolts
Figure 7