Draper E Series Kurulum ve Kullanım Talimatları - Sayfa 4
Projeksiyon Perdesi Draper E Series için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları indirin. Draper E Series 4 sayfaları. 220v ultimate access
Ayrıca Draper E Series için: Kurulum ve Kullanım Talimatları (4 sayfalar)
220V Ultimate Access Series E & V by Draper
INTERNAL SCREEN WIRING
Green/Yellow
(Motor Ground)
Brown (Down)
Black (Up)
Blue (Common)
GND
N
To
230 VAC
L1
Line
INTERNAL SCREEN WIRING
Blue (Common)
Black (Up)
Brown (Down)
Green/Yellow
(Motor Ground)
N
To
230 VAC
L1
Line
GND
Single Station Control/Einstationsbedienung/
Single Station Control/Einstationsbedienung/
Dashed wiring
by installer/
Gestrichelte Verkabelung
durch Installateur/
Câblage en pointillés
par l'installateur
Standard Wiring Diagrams
Internal LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
Green/Yellow (Ground)
Red-to screen (directional)
Brown-to screen (directional)
White -Common to screen & 230V AC Neutral
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Location of key
operated on-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
External LVC-IV - Single or Multiple
Projection Screen Wiring Diagram
White-Common to screen & 230V AC Neutral
Red-to screen (directional)
Brown-to screen (directional)
Yellow-to 230V AC-Hot
Black-to 230V AC-Hot
Green/Yellow (Ground)
Location of key
operated 0n-off
switch if furnished.
Dashed wiring by electrician
Low voltage wiring by others
Wiring Diagrams—220V Standard Motor
Commande monoposte
Commande monoposte
CE Approved/CE-zugelassen/Homologuée CE
CE Approved/CE-zugelassen/Homologuée CE
Internal Screen Wiring/Interne
Internal Screen Wiring/Interne
Projektionsflächenverkablung/Câblage interne de l'écran
Projektionsflächenverkablung/Câblage interne de l'écran
Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)
Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)
Brown/Braun/Marron-220v (Down/Ab/Bas)
Brown/Braun/Marron-220v (Down/Ab/Bas)
Black/Schwarz/Noir-220v (Up/Auf/Haut)
Black/Schwarz/Noir-220v (Up/Auf/Haut)
Green-Yellow/Grün-Gelb/Vert-jaune
Green-Yellow/Grün-Gelb/Vert-jaune
(Motor Ground/Motorerdung/
(Motor Ground/Motorerdung/
mise à la terre du moteur)
mise à la terre du moteur)
Control
Control
switch/
switch/
Kontrollschalter/
Kontrollschalter/
Commutateur de commande
Commutateur de commande
Dashed wiring
by installer/
Gestrichelte Verkabelung
durch Installateur/
220v,
220v,
Câblage en pointillés
50 Hz.
50 Hz.
par l'installateur
www.draperinc.com
Receiver
Button
Inputs/Outputs
Receiver
Button
Multiple Station Control/Mehrstationsbedienung/
Multiple Station Control/Mehrstationsbedienung/
Commande multiposte
Commande multiposte
Not CE Approved/Nicht CE-zugelassen/Non homologuée CE
Not CE Approved/Nicht CE-zugelassen/Non homologuée CE
Internal Screen Wiring/Interne
Internal Screen Wiring/Interne
Projektionsflächenverkablung/Câblage interne de l'écran
Projektionsflächenverkablung/Câblage interne de l'écran
Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)
Blue/Blau/Bleu-220v (Common/Gemeinsam/Commun)
Brown/Braun/Marron-220v (Down/Ab/Bas)
Brown/Braun/Marron-220v (Down/Ab/Bas)
Black/Schwarz/Noir-220v (Up/Auf/Haut)
Black/Schwarz/Noir-220v (Up/Auf/Haut)
Green-Yellow/Grün-Gelb/Vert-jaune
Green-Yellow/Grün-Gelb/Vert-jaune
(Motor Ground/Motorerdung/
(Motor Ground/Motorerdung/
mise à la terre du moteur)
mise à la terre du moteur)
Red/Rot/Rouge
Red/Rot/Rouge
Blue/
Blue/
Blau/
Blau/
Bleu
Bleu
Black/Schwarz/Noir
Black/Schwarz/Noir
Control
Control
Red/Rot/Rouge
Red/Rot/Rouge
Blue/
Blue/
switches/
switches/
Blau/
Blau/
Kontrollschalter/
Kontrollschalter/
Bleu
Bleu
Commutateurs
Commutateurs
Black/Schwarz/Noir
Black/Schwarz/Noir
de commande
de commande
Red/Rot/Rouge
Red/Rot/Rouge
Blue/
Blue/
Blau/
Blau/
Bleu
Bleu
Black/Schwarz/Noir
Black/Schwarz/Noir
Dashed wiring
Dashed wiring
by installer/
by installer/
Gestrichelte Verkabelung
Gestrichelte Verkabelung
durch Installateur/
durch Installateur/
Câblage en pointillés
Câblage en pointillés
par l'installateur
par l'installateur
220v, 50 Hz.
220v, 50 Hz.
(765) 987-7999
Page 4 of 4
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Low Voltage
Trigger
*A maximum of six (6)
3-28 VDC
LVC-IV modules can be
linked together.
IR Eye Input
3 Button Wall Switch
DOWN - Black
COM - White
UP - Red
Electrically Straight
Data Cable to more
LVC-IV modules*
RS232/485
Inputs/Outputs
Low Voltage
Trigger
*A maximum of six (6)
3-28 VDC
LVC-IV modules can be
linked together.
IR Eye Input
Wall Switch
Wall Switch