Drawell LBI-175B-N Kullanıcı Kılavuzu - Sayfa 6
Laboratuvar Ekipmanları Drawell LBI-175B-N için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Drawell LBI-175B-N 16 sayfaları.
Decrease
Run/Stop
3.Temperature setting
Press the set key and the temperature setting number in the (4) display window will flash,
can set the desired temperature by pressing the shift key, Increase key and decrease key.
4.Temperature parameter table
Parameter
Parameter
indication
Lc
password
deviation
TH
temperature
deviation
TL
temperature
Deviation
Tb
correction
TA
correction
Press the key in the setting state to decrease the
setting value.
In the normal display state, press this key to start
or stop the operation
Description for parameter function
name
When "Lc = 103", you can view and
modify the parameter value.
If "Measured value> Set value +
TH", upper deviation alarm will be
turned on and temperature output will
Upper
be turned off.
During the alarm, the temperature
Over
alarm relay has output, the buzzer
beeps, the alarm indicator lights up,
alarm
the temperature unit flashes quickly,
click any key to cancel the beep, and
the relay turns off the output.
If "measured value <set value +
TL", there will be he lower deviation
alarm.
Lower
During the alarm, the temperature
alarm relay has an output, the buzzer
Over
beeps, and the temperature unit
flashes slowly. Click any key to cancel
alarm
the beep.
Note: When "TL = 0", this function is
invalid.
Correct the error caused by sensor
(low temperature) measurement;
Tb = actual temperature value-meter
Correct the error caused by sensor
(high temperature) measurement;
Slope
TA = 1000 * (actual temperature
value-instrument measurement
measurement value.
value) ÷ instrument
measurement value.
6
Factory default
0
(0~20.0℃)
5.0
(-50.0~0℃)
0
(-99.9~99.9℃)
0
(-999~999)
0