Electrolux C290R Kullanım ve Kurulum Kılavuzu - Sayfa 17
Yıkayıcı Electrolux C290R için çevrimiçi göz atın veya pdf Kullanım ve Kurulum Kılavuzu indirin. Electrolux C290R 20 sayfaları. Hydro-extractor
Ayrıca Electrolux C290R için: Kullanım Kılavuzu (24 sayfalar), Servis Kılavuzu (41 sayfalar)
- 1. Table of Contents
- 1. Instruction for Use
- 1. General, Safety
- 1. Procedure for Use
- 1. Maintenance
- 1. Unpacking, Open the Lid, Come with All Types
- 1. Positioning, Drains
- 2. Installation
- 2. Quality Requirements, Concreting of Foundation
- 2. Concreting, Procedure
- 2. Attachment and Fitting of Hydro-Extractor
- 2. Technical Data
- 2. Electrical Installation
- 2. Voltage Change
- 2. Test Runs
Test run
When the installation work has been
completed, a functional check must be carried
out as follows:
1. Make sure that the main switch is in OFF
position and that the drum is empty.
Close the lid.
2. Turn the main switch ON. The green lamp for
- button must now flash. Press the button
to open the lid.
If the hydro-extractor receives a wrong phase
sequence, relay 2 of the automatic controls
(the relay normally used for braking) will be
activated and the hydro-extractor will start
without the lid being opened.
If this happens, the main switch must be
turned off and two of the phases in the
automatic controls must be swapped, before
a new functional test is carried out.
3. Close the lid. The hydro-extractor will state:
• The lamp at the START button flashes.
• The lamp at the
Push the START button.
Check the spinning time. The preset time is 5
minutes; this can be changed.
Check that the green lamp at the START
button is lit during spinning. When the time has
passed, the green lamp for lid opening must
flash. Press the
Check hat the drum has in fact stopped when
the lid is opened.
4. Close the lid and push START. When the
drum has reached its full speed, push STOP
button. The drum must now stop and it must
be possible to open the lid by pressing
the
- button.
NB!
If the yellow lamp at the STOP button
flashes, the hydro-extractor has a fault.
5. Clean the hydro-extractor after completing
the test run.
487 22 52 21 - Cent. 240, 260, 290, GB
Installation
- button lights up.
- button.
1
2
17
Relay 2
Relay 1
1956
1968