Carlisle Brass CDG420 Kurulum Talimatları - Sayfa 2

Kapı açma sistemi Carlisle Brass CDG420 için çevrimiçi göz atın veya pdf Kurulum Talimatları indirin. Carlisle Brass CDG420 2 sayfaları. Template size 2-4 door closer c/w fig. 6 bracket

INSTALLATION - FIG 1 APPLICATION - ANGLE OF OPENING LIMITED TO 180º
INSTALLATION - FIG 1 APPLICATION - ANGLE OF OPENING LIMITED TO 105º
Fig 1 - Standard Application (Door closer fitted on pull face of door)
1.
Ensure that the door and surrounding frame are in good condition, flush with one another and that the door
closes freely.
2.
Please refer to the supplied 1:1 scale fitting template for clockwise closing and anti-clockwise closing doors.
Ensure you select the correct details for the doors application and drill pilot holes in door and frame accordingly.
3.
Detach the main arm from the threaded section at the knuckle joint, and attach the main arm onto the door closer pinion at
an angle of 90°, then fasten securely with machine bolt provided.
The end of the door closer with the adjustement valves must be positioned towards the hinges (in Fig. 1) to ensure the arm
is fitted with the correct pinion point.
4.
Secure the closer body to the door, ensuring the adjustment valves face the direction of the hinges.
Fix the power shoe of the threaded arm to the frame (Refer to Power Shoe Detail on page 1).
5.
The final resting position of the threaded arm once attached to the main arm should be 90° from door face.
Adjust the threaded section accordingly. When satisfied with position, attach both arm sections at the knuckle joint
and tighten bolt on screwed section. Fix dust cover to the bottom pinion.
6.
Operate the door and adjust the closing and/or latching speed valves as necessary.
Do not unwind any of the valves completely as this will cause the unit to fail.
7.
When applicable, place closer cover over the body of the closer it is securely attached and hooked over the fixing nut for the
arm.
INSTALLATION - FIG 6 APPLICATION - ANGLE OF OPENING LIMITED TO 105º
Fig 6 - Parallel Mount Application (Door closer fitted on push face of door)
1.
Ensure that the door and surrounding frame are in good condition, plumb and that the door closes freely.
2.
Please refer to the supplied 1:1 scale fitting template for clockwise closing and anti-clockwise closing doors.
Ensure you select the correct details for the doors application and drill pilot holes in door and frame accordingly.
3.
Secure the Fig. 6 bracket to the underside of the frame.
4.
Detach the main arm from the threaded section at the knuckle joint, and attach the main arm onto the door
closer pinion at an angle of 45° (door opening direction), then fasten securely with machine bolt provided.
The end of the closer without the latching and closing speed adjustment valves must be positioned away from the
hinges (in Fig.6) to ensure the arm is fitted on the correct pinion point.
5.
Carefully fully adjust (clockwise) closing speed valve 1. Pull the main arm back by approx 90° so it is away from
the doorside of the closer body. Secure closer body to the door.
Fix the power shoe of the threaded arm section to the Fig. 6 bracket (Refer to Power Shoe Detail on page 1).
6.
Attach the threaded arm to the knuckle joint of main arm and adjust the length accordingly, then tighten the fixing bolts.
The final resting position of the main arm should be horizontal with face of door.
Fix dust cover to the bottom pinion.
7.
Operate the door and adjust the closing and/or latching speed valves as necessary.
Do not unwind any of the valves completely as this will cause the unit to fail.
8.
When applicable, place closer cover over the body of the closer it is securely attached and hooked over the fixing nut for the
arm.
Check that the door closer closes the door correctly and adjust as necessary.
Ensure fixing screws are tight and periodically apply light oil or grease to arm pivot joints.
Failure to install this product as per these instructions and dimensions will negate guarantee.