call bosch service at 800-944-2904 if:
1. Any of the burners do not light.
2. The broil burner or bake burner flame goes out
before it reaches 350° F.
3. Any of the burners continue to burn yellow.
If flame adjustment is necessary, continue to "Adjust
the Flame". Otherwise, installation is complete at
this point.
adjust the Flame (if necessary)
,
WarnIng
Allow Burner(s) to cool before attempting to
remove them!
adjust broil burner air shutter (if necessary)
More Open:
•Less Yellow Flame
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or blowing
The air shutter is located on the back end of the
broil burner. It is attached to the top of the oven
cavity with 7 screws. Remove screws and gently
pull broil burner assembly straight out being care-
ful not to detach electrical wires. Place broil burner
against back wall of oven cavity. Loosen screw and
turn shutter. Close the shutter if the flame is lifting
or blowing or not carrying over; Open the shutter if it
is too yellow. Tighten screw. Replace broil assembly
being careful to feed all wires through the back of
the oven. Reinsert all 7 screws.
Shutter
Screw
note: the air shutter on the broil burner fits over
theorifice when installed correctly.adjust bake
burner air shutter (if necessary)
Shutter
More Open:
•Less Yellow Flame
The oven burner air shutter is located near the oven
regulator. Reach it through the access hole in the
interior back panel of the warming drawer (loosen
screws and remove access panel). Loosen screw on
shutter. Close the shutter if the flame is lifting or
blowing or not carrying over; Open the shutter if it is
too yellow. Tighten screw. Reattach cover plate and
replace warming drawer.
More Closed:
•Less Blue Flame
•More Carryover
•Less lifting or blowing
15