24.2 Appliance dimensions
You will find the dimensions of the appliance here
24.3 Installation in a tall unit
Observe the installation dimensions and the installation
instructions when installing in a tall unit.
¡ To ventilate the appliance, there must be a gap of
20 mm between all intermediate floors and the wall.
¡ If the tall unit has another back panel in addition to
the element back panels, this must be removed.
¡ Only fit the appliance up to a height which allows
accessories to be easily removed.
24.4 Corner installation
Observe the installation dimensions and the installation
instructions when installing in a corner.
¡ To ensure that the appliance door can be opened,
you must take the minimum dimensions into consid-
eration when installing in a corner. The dimension
is dependent on the thickness of the unit front and
the handle.
24.5 Electrical connection
In order to safely connect the appliance to the elec-
trical system, follow these instructions.
¡ The appliance corresponds to protection class I and
must only be operated with a protective earth con-
nection.
¡ The fuse protection must correspond to the power
rating specified on the appliance's rating plate and
to local regulations.
¡ The appliance must be disconnected from the
power supply whenever installation work is being
carried out.
¡ Contact protection must be ensured during the in-
stallation.
Electrically connecting an appliance without a
protective contact plug
Note: Only a licensed professional may connect the ap-
pliance. Damage caused by incorrect connection is not
covered under the warranty.
An all-pole isolating switch must be integrated into the
permanent electrical installation according to the install-
ation regulations.
Identify the phase and neutral conductors in the
1.
socket.
The appliance may be damaged if it is not connec-
ted correctly.
Connect the hob in accordance with the connection
2.
diagram.
The yellow/green wire for the safety earth terminal
must be 10 mm longer on the appliance side than
the other wires.
See the rating plate for the voltage.
Connection 3N~ / 2N~ / 1N~: Use a H05VV-F
mains power cable or one with a higher rating.
Installation instructions en