Electrolux 534185 Şartname Sayfası - Sayfa 2

Bulaşık Makinesi Electrolux 534185 için çevrimiçi göz atın veya pdf Şartname Sayfası indirin. Electrolux 534185 5 sayfaları. Warewashing 105′′ multi tank conveyor dishwasher with energy saving device (esd) wt105

Electric
Supply voltage:
534182 (WT105AL208)
534183 (WT105AR208)
534184 (WT105AL240)
534185 (WT105AR240)
Dishwasher requires two separate electrical service connections. Refer
to below table for Amp requirements.
Connection 1:
208 V/3ph/60Hz
240 V/3ph/60Hz
Connection 2:
208 V/3ph/60Hz
240V/3ph/60Hz
Total Amp Load:
208 V/3ph/60Hz
240 V/3ph/60Hz

Exhaust Requirements

Unit supplied as standard with extended vent hoods
(can be removed during installation if not required).
Exhaust extraction not more than 100 CFM
Refer to installation diagram for minimum exhaust hood
installation height .

Key Information

Productivity racks per hour
(max speed):
Productivity racks per hour
(min speed):
Table to Table connection:
Number of Tanks:
Height with door open:
Charging hole size (width):
Charging hole size (height):
Shipping weight:
Shipping width:
Shipping depth:
Shipping height:
Shipping volume:
Noise level:
Unit predisposed to accept external detergent dispensers, detergent
probes and rinse aid dispensers.
Warewashing
105" " " " " Multi Tank Conveyor Dishwasher with Energy Saving Device (ESD) WT105
208 V/3ph/60Hz
208 V/3ph/60Hz
240 V/3ph/60Hz
240 V/3ph/60Hz
71A
62A
69A
62A
136.1A (44.4 kW)
121.1A (44.4 kW)
250 racks / 4500 dishes
(average 18 dishes per rack)
150 racks / 2700 dishes
(average 18 dishes per rack)
106-1/4" (2698 mm)
3
83-7/16" (2119 mm)
20-7/8" (530 mm)
19-3/4" (501 mm)
1327 lb (602 kg)
129-15/16" (3300 mm)
40-15/16" (1040 mm)
81-1/8" (2060 mm)
3
148 cu.ft (4.18
)
<70 dBA
105" Multi Tank Conveyor Dishwasher
with Energy Saving Device (ESD) WT105
Water
Inlet Water supply pressure:
Inlet Cold Water Supply Temperature
for pre wash and rinse section:
Inlet Hot Water Supply Temperature
for wash section:
Inlet Water supply hardness:
Incoming Cold Water line size
(pre wash):
Incoming Hot Water line size
(wash section):
Incoming Cold Water line size (rinse): G 3/4"
Drain line size (pre wash section):
Drain line size (wash section):
Drain line size (rinse section):
Hot Water consumption: Gallons/hr:
Cold Water consumption: Gallons/hr:
Water consumption/rack:
Pre wash Temperature:
Pre wash tank size:
Pre wash pump power:
Pre Wash water flow:
Wash Temperature:
Wash tank size:
Wash pump power (top wash arms):
Wash pump power (lower wash arms): 1.5 hp (1.2 kW)
Power Rinse Temperature:
Power rinse tank size:
Rinse pump power:
Final Rinse Temperature:
Final Rinse water flow:
Hot water booster capacity:
Initial fill Hot Water requirements:
Initial fill Cold Water requirements:
Warewashing
22 – 102 psi (150 – 700 kPa)
39 – 59 °F (4 - 15 °C)
140 °F (60 °C)
4-8 gpg (7-14 °fH) max
G 3/4"
G 3/4"
G 1-1/2"
G 1-1/2"
G 1-1/2"
4 gal/hr (15 liters)
83 gal/hr (315 liters)
0.3 gal/rack (0.75 l/rack)
< 105 °F (<40 °C)
11.8 gal (45 liters)
0.5 hp (0,37 kW)
39 gal/min (150 l/min)
160 – 172 °F (71-78 °C)
40 gal (150 liters)
3 hp (2.2 kW)
160 – 172 °F (71-78 °C)
6 gal (23 liters)
0.4 hp (0.32 kW)
180 – 194 °F (82-90 °C)
79 gal/min (300 l/min)
3 gal (11.3 liters)
40 gal (150 liters)
11.8 gal (45 liters)
10-29-08