Ancona Advanta Pro III 36 Kullanıcı Talimatları - Sayfa 5

Havalandırma Davlumbazı Ancona Advanta Pro III 36 için çevrimiçi göz atın veya pdf Kullanıcı Talimatları indirin. Ancona Advanta Pro III 36 12 sayfaları.

Ancona Advanta Pro III 36 Kullanıcı Talimatları

GENERAL INSTALLATION INSTRUCTIONS

A: GENERAL
 Carefully unpack the hood but do not remove any
protective film until after installation to avoid
accidental damage or scratching. Place filters
somewhere safe for the same reason.
 Check for damage, and lay out the hood pieces and
parts.
 Range hoods do not come with wall or ceiling screws,
as the type of structure determines the type of screws.
Check that you have the right tools. In addition to
marking and measuring tools, a hammer, screwdrivers,
pliers and scissors, you may need sheet metal sheers,
and wire strippers. Safety glasses are recommended.
UNDERCABINET RANGE HOOD INSTALLATION
This range hood model is designed to be installed under kitchen cabinets.
If replacing a different model, check the location of the air exhaust in case it does not line up with the new model;
The ducting location may have to be adjusted to the existing wall opening;
If the ventilation system is equipped with an external air duct with a different diameter, apply a reduction fitting.
A 6‖ Ø or rectangular 3‖ X 10‖ ducting is recommended for maximum performance and safety.
Section A: Select venting option
This unit offers 2 venting options:
A- Top venting (vertical) using 6‖ round or rectangular 3‖ X 10‖ damper
B- Rear venting (horizontal) using rectangular damper.
A1- Top venting Roof Exhaust
B: ELECTRICAL CONNECTION
 This range hood must be grounded. If the dwelling
wiring is not 2-wire with a ground wire, a ground must
be provided by the installer.
 Install a 5.08 X 10.16 cm (2‖ X 4‖) wall outlet box and
3-blade 125 Volts, 15 amp grounded receptacle.
 Use wire nuts to connect incoming ground, neutral and
hot.
 Push wires into the junction box and replace cover. Be
sure wires are not pinched.
C- INSTALLATION DISTANCE
 Hood should be placed at a minimum distance from
the range top of:
– 61 cm (24‖) for electric cooking surface
76 cm (30‖) for Gas Cooking Surface
A2- Top venting Wall Exhaust
B- Rear Venting
5