Formech 450 Kurulum, Kullanım ve Servis Kılavuzu - Sayfa 6

Isıtıcı Formech 450 için çevrimiçi göz atın veya pdf Kurulum, Kullanım ve Servis Kılavuzu indirin. Formech 450 14 sayfaları. Single heater vacuum forming machine

Initial Assembly

The machine should be sited on a level concrete floor. Dusty or draughty areas will
compromise machine performance but it is important to allow enough space around the
machine to allow access into the various panels and to ensure a good airflow to prevent
overheating. During all of the following installation ensure that the power supply is properly
isolated.

Electrical connection

220-240V Single phase
An electric supply of correct voltage, current & frequency is required. An isolating switch with
facility to be locked in 'OFF' position and capable of handling full current should be wall
mounted, within easy reach of the operator.
This machine must be properly earthed in accordance with local regulations.

Heat cover assembly and fitting

The Heater Cover is attached to the rear heat shield plate and is fitted directly to the rails
using the small orange-capped screws and nuts, one on each side.

450 Heater - no fitting required.

The heater is attached to the machine and located with the heater wheels sitting on the rails.
The heater is connected to the isolator switch located at the rear of the machine with electrical
conduit.

Attaching the stabiliser bar

The kit comprises two sidepieces and one stabiliser bar.
1
Remove the two screws from the bottom left hand panel.
2
Align stabiliser sidepiece with panel holes.
3
Insert screws. DO not tighten at this stage.
4
Repeat procedure on right hand side panel.
5
Now place stabiliser bar between both sidepieces and insert screws.
6
Tighten up all six screws
Fitting of rear stabiliser is now complete.

Optional cooling system

Attaching the Cooling System;
1
Fit the gantry to the two heater tracks at the boltholes on either side of the moulding area
with the four nuts and bolts supplied.
2
Fit the fan unit to the cross section of the gantry using the attached bracket. Before
tightening the bracket position the fan so that the cool air is directed over the forming
area.
3
Plug the fan unit to the socket position at the back of the machine.
Using the Cooling System;
The cooling system is brought into operation by switching on the AUX paddle switch located
next to the PUMP switch on the front panel.
Formech 450