3.2.1
Switch Function and Options
The R247 has several user-configurable options that are accessed by DIP switches mounted
on the circuit board. These options are read by the R247 only on power-up, so the power must
be disconnected and reconnected after any change is made.
Switch 1: Night Intensity (for MUTCD setting)
OFF – 35 candela
ON – 10 candela
Switch 2 and 3: Day Intensity
2 OFF, 3 OFF - 124 candela
2 ON, 3 OFF
2 OFF, 3 ON
2 ON, 3 ON
Switch 4: ALC Disable
OFF – ALC Enabled
ON – ALC Disabled
Switch 5: ALC Disable
Not Used
Switch 6, 7 and 8: Flash Pattern
Switch Settings Flash times, in seconds
6
7
8
On
Off
Off
Off
0.5
Off
Off
On
0.3
Off
On
Off
0.1
Off
On
On
0.15 0.1
On
Off
Off
0.1
On
Off
On
0.5
On
On
Off
0.1
On
On
On
0.1
3.3
Factory Default Settings
The factory default configuration is all switches set to the OFF position – this sets 124 candela
daytime intensity and 35 candela nighttime intensity, with ALC enabled and MUTCD standard
flash pattern.
- 250 candela
- 400 candela
- 400 candela
Off
On
Off
On
0.5
0.7
0.05 0.1
0.05 0.1
0.15 0.1
0.15 0.5
0.2
1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
Document number: MAN_ROAD R247 Owner's Manual 37224_vE
Owner's Manual | Model R247
Approx.
Brightness (Cd) Description
Off On Off
250
417
0.5
375
319
375
375
0.5
417
0.1 0.1 0.5 375
Carmanah Technologies Corp. Copyright © 2006
Last revised: November 7, 2006
MUTCD standard
Brighter than MUTCD
Three quick flashes
Three slower flashes
Fast flashing
Slow flashing
Three flashes
Four Flashes