Formula TECH SUSPENSION TJ2 Kullanıcı Kılavuzu - Sayfa 8

Bisiklet Aksesuarları Formula TECH SUSPENSION TJ2 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Formula TECH SUSPENSION TJ2 14 sayfaları. Shock absorber

Pressure Check

Required tools:
Bench vise, Formula Pump.
Procedure:
You can find the complete tutorial on
Formula's YouTube channel.
1. Remove the uniball spacers and place the shock absorber in a bench vise;
2.
It's highly recommended to use a
Formula Pump. Using different tools could cause issues;
3. Unscrew the reservoir cap;
4. Screw the air pump to the reservoir valve without enabling the valve duct;
5. Pressurise the pump at 200 psi;
6. Enable the valve duct and the pressure in the pump will be normalised with the pressure inside the reservoir;
7. Check the pressure and ensure it's between 10 and 12 bar;
If the pressure is lower than 10 bars, inflate the shock absorber with nitrogen. Do not use air to inflate the shock
absorber as it could affect its performance and correct functioning.
8. If the pressure is correct, close the pump valve duct and remove the pump. Screw the reservoir cap;
9. Remove the shock absorber from the bench vise and reassemble the uniball spacers.
-End of Procedure-