Troubleshooting
Symptom
Fixture won't turn on...
Fixture won't turn on...
Fixture turns off...
Fixture turns on...
Fixture dim...
Green light on (night mode)...
Green light flashing (night mode)...
10
Circumstances
...after test button pressed
...at night time
... in the middle of the night
... during the day
... during the night
... during the day
... during the night
© 2015, Carmanah Technologies Corporation. EG320-340_UserManual_76116RevA
EG320/EG340 USER MANUAL
MAiNtENANcE & PRodUct cARE
Possible Cause
(solution)
Sunlight interfering with communications (try again later
in the day)
Too far away (get closer)
Programmer battery dead (replace batteries)
Programmer not aimed at EMS receiver (aim carefully)
Blown battery fuse (check wiring, replace battery fuse)
Fixture wiring problem (check fixture wiring for short/
open circuit)
EMS programmed incorrectly (check programmer knob/
switch settings, reprogram EMS)
Blown battery fuse (check wiring, replace battery fuse)
Solar panel shaded, causing drained batteries & low-
voltage disconnect (prune trees, move pole)
Solar panel wiring problem caused drained batteries &
low-voltage disconnect (check SOLAR PANEL wiring)
Fixture wiring problem (check fixture wiring for short/
open circuit)
EMS programmed to run for specific time after dusk.
This may be correct operation. Please check with your
Carmanah distributor.
Solar panel shaded, causing drained batteries & low-
voltage disconnect (prune trees, move pole)
EMS not programmed, or programmed incorrectly
(check programmer knob/switch settings, reprogram
EMS)
Solar panel wiring open circuit causing system to think it
is night. Check Solar panel wires & connectors.
EMS programmed to run for specific time after dusk.
This may be correct operation. Please check with your
Carmanah distributor
Solar panel shaded, causing drained batteries & low
voltage disconnect (prune trees, move pole)
Solar panel wires not connected properly (check Solar
panel wires & connectors)
Short between battery & Solar panel wiring (check all
wiring)