ANDELI TIG-250PL ACDC Operatör El Kitabı - Sayfa 19

İnvertör ANDELI TIG-250PL ACDC için çevrimiçi göz atın veya pdf Operatör El Kitabı indirin. ANDELI TIG-250PL ACDC 20 sayfaları. Inverter ac/dc pulsed tig welder

ANDELI TIG-250PL ACDC Operatör El Kitabı
Factory setting
0
Stop: Crater arc current (No such function)
Post-flow
Unit
S
Setting range
0.1—10
Factory setting
3
Hz: AC frequency (only with TIG-AC)
Unit
Hz
Setting range
50—250 (Iw<50A)
50—200 (50A≤Iw<100A)
50—150 (100A≤Iw<150A)
50—100 (150A≤Iw<200A)
Balance (only with TIG-AC)
Balance adjustment is mainly used to set the adjustment of eliminating metal-oxide (such as
Aluminium,
Magnesium and its alloy) while AC output.
Unit
%
Setting range
15—50
Factory setting
15
(9) Welding voltage/other parameter display
Indicate the welding voltage or other parameter.
Before the start of welding, the right-hand display shows the pre-set value of Tpr, Tup, Dcy, Fp,
Tdown andTpo.
There is a 3s time-lag, open-circuit voltage is displayed after adjusting those parameters.
MAINTENANCE AND TROUBLESHOOTING
17