Digital Control Only Power Supply: Digital Controls driving Westfalia 24v Feeders: Existing 24vAC WS Supply for feeders.
Control Supply Transformer:
0-12: 0-12: 25VA
230v AC Primary
DANGER: Mains Voltage
T5AMP FUSE
DATA SHEET: 08D
DIGITAL CONTROL
CONVERSION
Disconnect mains supply before removing cover.
Do not drill fixing or cable
entry holes in the top or
sides of the casing.
Use the recommended
cable cross sectional area
(csa/mm) and where
possible the specified
colours.
Replace fuses with the
specified values AFTER the
cause of a blown fuse is
traced and corrected.
Earth to
chassis
230v AC Mains IN for
Control Supply
Transformer.
Chassis is earthed via
fixing screw.
Must be supplied from a
2-pole switched outlet.