Anderson POWER EBC E80 Montaj Talimatları - Sayfa 2
Kablolar ve konektörler Anderson POWER EBC E80 için çevrimiçi göz atın veya pdf Montaj Talimatları indirin. Anderson POWER EBC E80 4 sayfaları. Female connector
Figure 5
7. Install terminated power contacts into the contact holder:
CAUTION: Observe proper polarity. The positive and negative pin sides are indicated in Figure 6.
a.
Line up the socket contact with the opening in the holder
b.
Push the contact forward until the snap feature grabs the contact shoulder
c.
Repeat with the other socket on the opposite side
Figure 7
9. Install the voltage pin into the housing: The pin installs in the hex shaped opening on the inside of the plug housing.
a.
Orient the pin for the desired voltage. With the dry or wet voltage pins, the inner numbers correspond to the
socket housing voltage.
b.
Push the pin forward, verifying that the pin is in the right orientation. (Figure 9)
c.
Once the front of the pin is equal with the front of the housing, use a screwdriver to push the pin further until it
snaps in place.
NOTE: Yellow universal key is not used with female housings
Larger "U" goes on the top
Figure 10
11. Install the optional handle on the top (polarity mark side) of the housing (Figure 11):
a. Align the two posts on the underside of the handle with the two holes on the housing.
b. Push down on the handle until the it is all the way down on the housing
c. Use the two self-tapping screws to secure the handle. Tighten to .7 to 1.0 N-M [6 – 9 in-lb] of torque.
Figure 12
Page 2 All Data Subject to Change Without Notice
© 2023 Anderson Power Products, Inc. All rights reserved. Anderson Power Products®, A® and the Anderson Power™ logo are registered trademarks of Anderson Power Products, Inc.
HEADQUARTERS: Anderson Power Products®, 13 Pratts Junction Road, Sterling, MA 01564-2305 USA T: +1 978-422-3800 F: +1 978-422-0128
Retention Feature
8. Install the fully assembled contact holder into the socket housing (Figure 7):
a.
Orient both the holder and the housing with polarity markings facing up.
b.
Slide the holder into the housing, lining up all contacts with their respec-
tive openings
c.
Push from the back of the holder until the holder locking tab snaps into
the rectangular/domed opening (Figure 8)
10. Secure the power cables using the cable clamps and self-tapping screws:
a.
Line up the top and bottom clamp with open pillars at the cable side of the housing (note the upper clamp
has a larger "U" and should be on the side with polarity markings). (Figure 10)
b.
Install the two screws in the open holes on the upper clamp.
c.
Hold the two clamps tight to the cable while tightening the screws. Auxiliary wires will pass through "U"
and may not be grabbed by the clamp.
d.
Tighten to .7 to 1.0 N-M [6 – 9 in-lb] of torque. (Figure 10)
If necessary to disassemble the connector, follow these instructions (Figure 12):
1.
Turn off all power sources
2.
Remove the top and bottom cable clamps (optional handle does not need to be removed)
3.
Slide a small flat screwdriver in through the back of the housing near the holder catch
4.
Carefully rotate the screwdriver towards the back of the housing. The blade must wedge between the catch
and the inside top of the housing, forcing the catch down.
5.
Grasp both power wires and pull back until the holder is clear of the housing. This may require some force.
ECN 2023-0043
6. Install the upper auxiliary contacts on the top of the holder (Figure 5):
a.
Pass the upper auxiliary leads on either side of the holder locking tab
b.
Snap the groove of each contact into the retention feature by pushing from
the center outward and down
c.
The contacts should hold securely in the retention feature
Contact Snap
Pos (+) Socket
Installs here
Figure 9
Neg (-) Socket
Installs here
Figure 6
Locking Tab engaged in hole
Inner numbers for female
housing voltage
Figure 11
Spec. No. 1S6676, Rev. 3