Carnival King 382DFCG23N Kullanıcı Kılavuzu - Sayfa 4

Fryer Carnival King 382DFCG23N için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Carnival King 382DFCG23N 14 sayfaları. Gas funnel cake fryers

Carnival King 382DFCG23N Kullanıcı Kılavuzu
www.CarnivalKingSupplies.com
gas FUNNEL CAKE FRYER Manual

Installation

Do not use the door or its handle to li the fryer.
Before installing the fryer, verify that the type of gas (natural or propane) is in conformity to the specifications
on the fryer data plate, which is located on the inside of the door panel. Make sure the fryer is configured for the
proper elevation.
CLEARANCES
• Minimum clearance from combustible construction:
6" (15 cm) from the sides of the fryer
6" (15 cm) from the back of the fryer
• Minimum clearance from noncombustible construction:
0" from the sides of the fryer
0" from the back of the fryer
• Between the fryer and any open-top flame units: 16" (41 cm)
• Allow space for servicing and operation.
LOCATION
• Install fryer in an area with su icient air supply for gas combustion at fryer burners.
• Do not obstruct the flow of combustion and ventilation air.
• Provide adequate clearance for air openings into the combustion chamber.
• Do not permit fans to blow directly onto fryer.
• Avoid wall-type fans, which create cross-currents within a room. Avoid open windows next to sides or back.
Codes and Standards
The fryer must be installed in accordance with:

IN THE UNITED STATES:

State and local codes, or in the absence of local codes, with:
• National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). Copies may
be obtained from The American Gas Association Accredited Standards Commi ee Z223,
@ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA,
1 Ba erymarch Park Quincy, MA 02169-7471.
• NFPA Standard #96 Vapor Removal from Cooking Equipment, latest edition,
available from the National Fire Protection Association, Ba erymarch Park, Quincy, MA.
• National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire
Protection Association, Ba erymarch Park, Quincy, MA. 02169-7471.
• In the commonwealth of Massachuse s all gas appliances vented through a
ventilation hood or exhaust system with a damper or with a power means of exhaust shall comply with 248
CMR.
IN CANADA:
Local codes
• CAN/CSA-B149.1 Natural Gas and Propane Installation Code (latest edition),available from
the Canadian Standards Association, 155 Queen Street, Suite 1300, O awa, Ontario Canada K1P 6L1.
• CSA C22.1 Canadian Electric Code (latest edition), available from the Canadian Standards Association, 155
Queen Street, Suite 1300, O awa, Ontario Canada K1P 6L1.
4
.