ANDERSON-NEGELE NSL-F-01 Kullanım Kılavuzu - Sayfa 4

Aksesuarlar ANDERSON-NEGELE NSL-F-01 için çevrimiçi göz atın veya pdf Kullanım Kılavuzu indirin. ANDERSON-NEGELE NSL-F-01 20 sayfaları. Continuous level sensor. sensors for food and biopharma.
Ayrıca ANDERSON-NEGELE NSL-F-01 için: Kullanım Kılavuzu (20 sayfalar)

NSL-F Series Operating Manual
3

Special features/advantages

Installation in tanks and feed vessels from above, below and diagonally (types NSL-F-00 and NSL-F-
02)
Lateral installation in tanks by means of an angulated sensor and various clamping systems (type
NSL-F-01)
Four-conductor sensor with 4...20-mA output signal
Due to the potentiometric measuring principle, calibration is not required after a change in medium
Individual setting/programming via PC or Simple User Interface
Current signal for measuring range, dry-run message and error message can be adjusted
The M12 plug connection can be aligned by turning the sensor head
2 individual configurable LEDs on the display unit
4

Options/accessories

Simple User Interface with small display (retrofittable)
Programming adapter MPI-200 (PC-based)
Tool for releasing the signal module
Preassembled PVC cable
PVC cable with M12 coupling of stainless steel 1.4305, IP 69k, unshielded
o
M12-PVC/4–5 m
o
M12-PVC/4-10 m
o
M12-PVC/4-25 m
PVC cable with M12 coupling of nickel-plated brass, IP 67, shielded
o
M12-PVC/4G–5 m
o
M12-PVC/4G–10 m
o
M12-PVC/4G–25 m
2.2 Factory certificate as per EN 10204 (product-contacting equipment only)
5

Installation and connection

Intended use
Information on mounting position
If the sensor is installed in the tank, the measurement signal will not be reliable in an area of 20 mm
(35 mm) from the sealing edge (see dimensional drawing). This means that the 4 mA or 20 mA signal is
located on the bottom weld seam of the measuring rod.
The continuous level sensor NSL-F is set to operate in aqueous media without requiring special set-
tings. In case of highly critical media or special tank contours (with inside fittings such as a pipe), it
may be necessary to adjust some parameters. The parameterization may be changed using the PC-
based MPI-200 programming adapter or the Simple User Interface. The setting can either be set or
changed directly on location or in the office in a dry simulation.
When setting the parameters, it must be ensured that the various authorization leve ls are enabled (see
"Associated setup mode" column). The Monitor and Adjust levels are not required for setting the NSL -
F
sensor.
These levels can be individually protected with a password and thus made available to specific
users/service personnel. The software in both the PC/MPI-200 and Simple User Interface features a tree
structure.
PVC cable, 4-pin, 5 m in length
PVC cable, 4-pin, 10 m in length
PVC cable, 4-pin, 25 m in length
PVC cable, 4-pin, 5 m in length
PVC cable, 4-pin, 10 m in length
PVC cable, 4-pin, 25 m in length
4