INSTALLATION INSTRUCTIONS
FIG. 18
ANTI-STREAMING TIMER: Times RTS (Request to Send). If RTS is asserted for a time greater than
Note: If the RTS signal is turned ON for a time greater than the Anti-Streaming Time Setting, then the RTS
will be ON, but the CTS will be RED (Off ) and the FAIL LIGHT will be GRN (Failure Asserted).
When the RESET button is pressed, the FAIL LIGHT switches to RED and the RTS/CTS works again.
Communication Networks
3 Corporate Drive • Danbury, CT 06810 • USA
Tel: 203-796-5300 • Toll Free: 1-888-678-9427
www.comnet.net
the Anti-Streaming settings, the electrical input is turned OFF permanently.
To RESET: Press the RESET button on the front panel.
RTS/CTS INDICATORS
RTS:
RED
RTS is OFF
GRN
RTS is ON
CTS:
RED
CTS is OFF
GRN
CTS is ON
ANTI-STREAMING
OFF
(Factory Default)
4 SECONDS
8 SECONDS
ANTI-STREAMING
RS-232/422 DROP AND REPEAT
TIMER
FDX55 SERIES
DATA TRANSCEIVER
16 SECONDS
32 SECONDS
64 SECONDS
INS_FDX55_REVB
01/22/09