Electrolux EGT6343 Kullanıcı Kılavuzu - Sayfa 12
Hob Electrolux EGT6343 için çevrimiçi göz atın veya pdf Kullanıcı Kılavuzu indirin. Electrolux EGT6343 20 sayfaları. 60cm wide xline ultraflat stainless steel gas hob with 4 burners and individual cast iron pan supports.
Ayrıca Electrolux EGT6343 için: Kullanıcı Kılavuzu (16 sayfalar)
12
www.electrolux.com
However, if the room has a door which
opens directly to the outside no air vent is
required even if the volume is between 5
m³ and 11 m³.
If there are other fuel burning appliances in
the same room, B.S. 5440 Part 2 Current
Edition, should be consulted to determine
the requisite air vent requirements.
For appliances installed in the Republic of
Ireland please refer to the NSAI- Domestic
Gas Installation I.S. 813 Current Editions
Table Four.
Location
The hob may be located in a kitchen, a
kitchen/diner or bed sitting room (with a
volume greater than 20 m³), but not in a
bathroom or shower room.
The minimum distance combustible
material can be fitted above the hob in line
with the edges of the hob is 400 mm. If it
is fitted below 400 mm a space of 50 mm
must be allowed from the edges of the
hob.
For appliances installed in the Republic of
Ireland please refer to NSAI- Domestic
Gas Installation I.S 813 Current Edition
Section 7- Permitted Locations of
Appliance.
8.3 Gas Connection
WARNING!
Any gas installation must be
carried out by a GAS SAFE
REGISTER installer.
Make sure that, once the hob is installed,
it is easily accessible for the engineer in
the event of a breakdown.
The manufacturer will not accept liability,
should the above instructions or any of the
other safety instructions incorporated in
this instruction booklet be ignored.
On the end of the shaft, which includes
the G 1/2" threaded elbow, adjustment is
fixed so that the washer is fitted between
the components as shown in the diagram.
Screw the parts together without using
excessive force.
A
B C
A) End of shaft with nut
B) Washer
C) Elbow
Connection to the gas supply should be
with either rigid or semi-rigid pipe, i.e.
steel or copper.
The connection should be suitable for
connecting to R 1/2 (1/2 BSP male
thread).
When the final connection has been
made, it is essential that a thorough leak
test is carried out on the hob and
installation.
Make sure that the main connection pipe
does not exert any strain on the hob.
If you use flexible metal pipes make sure
that they agree to ISO 10380 and ISO
10807 standards. Be careful they do not
come in touch with mobile parts or they
are not squeezed. Also be careful when
the hob is put together with an oven.
CAUTION!
It is important to install the
elbow correctly, with the
shoulder on the end of the
thread, fitted to the hob
connecting pipe.
CAUTION!
Failure to ensure the correct
assembly will cause leakage
of gas.
CAUTION!
Make sure that the gas
supply pressure of the
appliance obeys the
recommended values.
Rigid connection:
Carry out connection by using metal rigid
pipes (copper with mechanical end).