3.4 Conversion to G 2.350 gas
For the G 2.350 gas
conversion please contact
our Authorised Service
Centre.
3.5 Adjustment of minimum
level
To adjust the minimum level of the
burners:
1. Light the burner.
2. Turn the knob on the minimum
position.
3. Remove the knob and the gasket.
4. With a thin screwdriver, adjust the
bypass screw position (A).
A
5. If you change:
• from natural gas G20 20 mbar to
liquid gas G30/G31 37 mbar, fully
tighten the bypass screw in.
• from liquid gas G30/G31 37 mbar
to natural gas G20 20 mbar, undo
the bypass screw approximately
1/2 of a turn (1/2 of a turn for Multi
Crown burner).
• from natural gas G20 20 mbar to
natural gas G2.350 13 mbar undo
the bypass screw approximately
1/4 of a turn (3/4 of a turn for Multi
Crown burner).
• from liquid gas G30/G31 37 mbar
to natural gas G2.350 13 mbar,
undo the bypass screw
approximately 1/2 of a turn (1 and
1/4 of a turn for Multi Crown
burner).
• from natural gas G2.350 13 mbar
to natural gas G20 20 mbar,
tighten the bypass screw
approximately 1/4 of a turn (3/4 of
a turn for Multi Crown burner).
• from natural gas G2.350 13 mbar
to liquid gas G30/G31 37 mbar,
fully tighten the bypass screw in.
6. Reassemble the gasket and the
knob.
WARNING!
Make sure the flame does
not go out when you quickly
turn the knob from the
maximum position to the
minimum position.
3.6 Electrical connection
• Make sure that the rated voltage and
type of power on the rating plate
agree with the voltage and the power
of the local power supply.
• This appliance is supplied with a
mains cable. It has to be supplied with
a correct plug which can hold the load
that the rating plate rates. Make sure
that you install the plug in a correct
socket.
• Always use a correctly installed
shockproof socket.
ENGLISH