3M 3MDW101 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 5

Su Filtrasyon Sistemleri 3M 3MDW101 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. 3M 3MDW101 8 sayfaları. Drinking water system

INSTALLATION INSTRUCTIONS (CONTINUED)
4. Determine length of tubing required from fi lter head as-
sembly to faucet and from water supply line to fi lter head
assembly by holding tubing in place ensuring it is of ap-
propriate length. Do not kink tubing as this will impede
water fl ow. If necessary, loop tubing around to avoid it
being kinked.
Cut tubing straight with a utility knife. (See Figure 3).
5. Locate the cold water stem on the underside of the faucet
fi xture. Place basin or towel under the cold water supply
valve. Unscrew the cold water feed tube from the faucet
stem. Locate the 1/4" Feedwater Adapter that came with
your Drinking Water System. Insert the black gasket into
the threaded adapter and tighten onto the 1/2" IPS Faucet
Stem undersink, making sure that 1/4" side connection is
accessible and not facing the wall. Make sure not to over
tighten.
Take the 1/2" IPS Cold Water Feed Tube and attach to the
Feedwater Adapter, making sure not to over tighten.
Locate the 1/4" Blue Tubing and insert into the 1/4" out-
let of Feedwater Adapter (Figure 4). See "Using Push-In
Fittings."
"Using Push-In Fittings"
To Attach Tubing
Push tubing in as far as it will go. Tubing must be inserted past
o-ring and hit backstop. Pull tube to ensure it is secured.
To reduce the risk associated with property damage due to water leakage:
• Ensure all tubing and fi ttings are secure and free of leaks.
6. Insert Blue Tubing from the 1/4" Feedwater Adapter into the fi lter INLET
fi tting as shown in Figure 5. Refer to the "Using Push-In Fittings" section
for detailed instructions.
7. Insert tubing from faucet into the fi lter OUTLET fi tting as shown in Figure
5. Refer to the "Using Push-In Fittings" section for detailed instructions.
8. Remove fi lter from box, and remove sanitary protective cap from replace-
ment fi lter. Ensure both o-rings are present on the new fi lter and are
seated into grooves; moisten o-rings with water. DO NOT use any petro-
leum products to lubricate the o-rings.
9. Align tabs of replacement fi lter with head assembly and insert replacement
fi lter into head assembly. Turn replacement fi lter to the right (clockwise)
until it stops (about 1/4 turn). The fi lter is now installed. (See Figure 5).
10. Turn water supply back on from the shutoff valve on cold water line. This
will pressurize the fi lter system and begin sending fi ltered water to the
faucet. Look for leaks. If leaks occur, see Troubleshooting Guide. Flush
the fi lter for four (4) gallons (approx. 5 minutes).
Correct
1/4" Blue
Tubing
To Release Tubing
Push in grey collet to release tubing. With collet
held, pull tubing straight out.
CAUTION
Collet
Backstop
5
Incorrect
Figure 3
1/2" IPS
Faucet Stem
Feedwater
Adapter
1/2" IPS
Cold Water
Feed Tube
Figure 4
OUTLET
INLET
Figure 5