3M 3MDW301 Kurulum ve Kullanım Talimatları Kılavuzu - Sayfa 5
Su Filtrasyon Sistemleri 3M 3MDW301 için çevrimiçi göz atın veya pdf Kurulum ve Kullanım Talimatları Kılavuzu indirin. 3M 3MDW301 9 sayfaları. Under sink water filtration
Ayrıca 3M 3MDW301 için: Hızlı Başlangıç Kılavuzu (2 sayfalar)
IMPORTANT INSTALLATION INSTRUCTIONS
For Use With Cold Water Only.
NOTE: Remove items from under the sink. Place catch basin there to collect small amounts of water that may run out
when disconnecting water supply lines.
1. Open faucet and turn off cold water supply to relieve pressure.
Install (2) quick connect fittings into head assembly using PTFE thread tape only.
2. Place a basin or a towel under the cold water supply valve. Remove cold side
riser tubing connection at cold water supply valve. Install feedwater adapter to
the cold water supply valve and reconnect the riser tubing.
3. Select and mark a location under the sink that allows access for filter change.
4. Using filter head assembly as a guide, mark hole locations so that there is
1 1/2" between the screws (see Figure 2), from center of each screw.
Install screws and washers halfway, so you can easily slip the bracket to wall
before firmly setting screws. NOTE: If you are mounting onto sheetrock or
drywall, use anchors or screws (not included).
When installed, the bottom of the filter should have a
minimum clearance of 3" from sink cabinet floor to
facilitate replacement filter change.
Fasten filter head assembly to wall with Phillips head mounting
screws supplied.
5. Cut tubing straight with a razor knife.
(See Figure 3).
Determine length of tubing required from filter head assem-
bly to feedwater adapter and from the filter head assembly to
the mounted Performance Indicator Device (PID) by holding
tubing in place ensuring it is of appropriate length. Do not kink tubing as this will impede water flow. If necessary,
loop tubing around to avoid it being kinked. (Refer to typical installation example found on Page 3). Install and
mount PID per PID mounting instructions on page 6, ensuring that the tubing from the bottom of the faucet can
reach the outlet fitting of the PID.
Connect 1/4" tubing from feedwater adapter to inlet side of filter head. (See "Using Push-In Fittings")
You may choose to install the optional Quick Connect 1/4" Ball Valve (included) in the line between the feedwater
adapter and the filter assembly.
"Using Push-In Fittings"
To Attach Tubing
(1) Push tubing in as far as it will go.
(2) Tubing must be inserted past o-ring and hit backstop.
Pull tube to ensure it is secured.
To Release Tubing
(3) Push in collet to release tubing.
(4) With collet held, pull tubing straight out.
To reduce the risk associated with property damage due to water leakage:
• Ensure all tubing and fittings are secure and free of leaks.
Correct
Collet
CAUTION
5
Figure 2
Incorrect
Figure 3
Backstop