12. Functions sequences
Lid Opening
The lid is opened by pressing the
button on the control panel. The
4
following conditions must be fulfilled before the lid will open:
• The machine power supply must be on
• The drum must be completely at a standstill i.e. rotation guards H1
(S4:2) and SW2 (S1:7) must have sent the opening signal.
The lid lock is released with the aid of the traction magnet Y1.
The control circuit of Y1 takes its voltage from the circuit board, output
S1:6, via rotation guard SW2. When the drum is completely still rotation
guard H1 gives the go-ahead signal for lid opening to the logicsection on
the circuit board (S4:2).
12.6
487 03 29 91