Electrolux C290R Servis Kılavuzu - Sayfa 18
Havalandırma Davlumbazı Electrolux C290R için çevrimiçi göz atın veya pdf Servis Kılavuzu indirin. Electrolux C290R 41 sayfaları. Hydro-extractor
Ayrıca Electrolux C290R için: Kullanım Kılavuzu (24 sayfalar), Kullanım ve Kurulum Kılavuzu (20 sayfalar)
Service
12
manual
12. Functions sequences
Lid Opening
The lid is opened by pressing the
button on the control panel. The
4
following conditions must be fulfilled before the lid will open:
• The machine power supply must be on
• The drum must be completely at a standstill i.e. rotation guards H1
(S4:2) and SW2 (S1:7) must have sent the opening signal.
The lid lock is released with the aid of the traction magnet Y1.
The control circuit of Y1 takes its voltage from the circuit board, output
S1:6, via rotation guard SW2. When the drum is completely still rotation
guard H1 gives the go-ahead signal for lid opening to the logicsection on
the circuit board (S4:2).
12.6
487 03 29 91