Split system
Ref.
Functions
1
Selecting of the DHW operating mode
(Domestic hot water).
2
Digital display.
3
Exit "ESC".
4
Navigation and setting.
5
Selecting the heating mode.
6
Information display.
7
Confirm "OK".
8
Selecting cooling mode.
9
RESET button
(Hold down the "RESET" key for 3 sec).
10
Selecting the heating mode.
11
Digital display.
12
Control knob.
13
Presence key.
Operation manual "1328 - EN"
- Definitions
- If the installation is fitted with a DHW tank.
- On : Production of DHW according to the time program.
- Off : Preparing the domestic hot water for stopping with the anti-frost
Marche
On
function active.
- Manual start button : Hold down the DHW key for 3 seconds. Switch from
"reduced" to "comfort" until the next time the ECS timer switches over.
Off
Arrêt
- Operating control. Readout of the current temperature, of the heating mode
and of any faults
- View the settings.
- Quit the menu.
- Selecting the menu.
- Setting parameters.
- Adjusting the ambient temperature setpoint.
-
Auto
Heating operating according to the heating programme
(Summer/winter mode switchover is automatic).
-
Constant comfort temperature.
-
Constant reduced temperature.
-
Stand-by mode with anti-frost protection
(Provided that the heat pump's electrical power supply is not interrupted).
- Various data (please see
-
Reading error codes.
-
Information concerning maintenance, special mode.
- Input into the selected menu.
- Confirmation of the parameter settings.
- Confirmation of the adjustment to the comfort temp. setting.
- If the installation is fitted with the cooling kit :
Auto
-
Cooling operating according to the heating programme
(Summer/winter mode switchover is automatic).
- Reinitialising the parameters and cancelling error messages.
Do not use during normal operation.
Auto
-
Heating operating according to the heating programme
(Summer/winter mode switchover is automatic).
-
Constant comfort temperature.
-
Constant reduced temperature.
-
Stand-by mode with anti-frost protection
(Provided that the heat pump's electrical power supply is not interrupted).
- Operating control. Readout of the current temperature, of the heating mode
and of any faults
- Adjusting the ambient temperature setpoint.
- Comfort / Reduced switchover.
.
page
15).
.