Technical Specifications

Dimensions (in cm):
Height
Width
Depth
Maximum absorbed power:
Motor absorption:
Lighting:
Length of the cable:

Mounting accessories included

1 Flange Ø 120 mm
1 Adapter Ø 120/100 mm
4 wood-screws 2,9 x 16

Electrical connection

Safety warnings for the electrician

The electric outlet should be placed on the wall inside the chimney.
The hood has a power cable, 150 cm, with earth connection and the
rated voltage is 220 - 240 V. Connect the hood to the mains supply via
a double pole switch which has 3 mm minimum separation between
the contacts. This switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured green and yellow must be connected to
the terminal which is marked with the letter E or by the earth symbol
(
), or coloured green or green and yellow;
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black, -
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.
16
137
510
285
220 W
140 W
2 x 40 W (E14)
150 cm