Daikin 3AMXF52A2V1B9 Kurulum Kılavuzu - Sayfa 11
Isı Pompası Daikin 3AMXF52A2V1B9 için çevrimiçi göz atın veya pdf Kurulum Kılavuzu indirin. Daikin 3AMXF52A2V1B9 20 sayfaları.
4.5.1
Specifications of standard wiring
components
Component
Power supply
Voltage
cable
Phase
Frequency
Wire type
Interconnection cable
(indoor↔outdoor)
Recommended circuit breaker
Earth leakage circuit breaker
Model
3MXM40
3- core cable 2.5 mm
3AMXM52,
H05RN-F (60245 IEC 57)
3AMXF52,
H07RN-F (60245 IEC 66)
3MXF52,
3MXM52,
3- core cable 4.0 mm
3MXF68,
H07RN-F (60245 IEC 66)
3MXM68,
4MXM68
4MXM80
3- core cable 4.0 mm
5MXM90
H07RN-F (60245 IEC 66)
Electrical equipment must comply with EN/IEC 61000-3-12, the
European/International Technical Standard setting the limits for
harmonic currents produced by equipment connected to public low-
voltage systems with input current >16 A and ≤75 A per phase.
4.5.2
To connect the electrical wiring to the
outdoor unit
1 Remove the switch box cover (1 screw).
1×
2 Connect the wires between the indoor and outdoor units so that
the terminal numbers match. Make sure to match the symbols
for piping and wiring.
3 Make sure to connect correct wiring to correct room.
a-A
a-B
a-C
a-D
a-E
e-A
a
Terminal for room (A, B, C, D, E)*
3(A)MXM+3(A)MXF+4MXM+5MXM
R32 Split series
3P600450-1C – 2020.05
220~240 V
1~
50 Hz
A
2
4-core cable 1.5 mm
or
2
2.5 mm
and applicable for
220~240 V
H05RN-F (60245 IEC 57)
B
MUST comply with
applicable legislation
A
B
2
16 A
20 A
2
2
25 A
32 A
b
c
d
e-D
e-C
e-B
e-E
b
Circuit breaker
c
Earth leakage circuit breaker
d
Power supply wire
e
Interconnection wire for room (A, B, C, D, E)*
*May differ depending on the model.
4 Tighten the terminal screws securely using a Philips
screwdriver.
5 Check that the wires do not disconnect by pulling them lightly.
6 Firmly secure the wire retainer to avoid external stress on wire
terminations.
7 Pass the wiring through the cutout on the bottom of the
protection plate.
8 Make sure the electrical wiring does not contact with the gas
piping.
2×
a
a
Wire retainer
9 Reattach the switch box cover and the service cover.
4.6
Finishing the outdoor unit
installation
4.6.1
To finish the outdoor unit installation
1 Insulate and fix the refrigerant piping and cables as follows:
d
c
a
e
b
f
g
a
Gas pipe
b
Gas pipe insulation
c
Interconnection cable
d
Field wiring (if applicable)
e
Liquid pipe
f
Liquid pipe insulation
g
Finishing tape
2 Install the service cover.
4.6.2
About standby electricity saving function
The standby electricity saving function:
▪ turns OFF the power supply to the outdoor unit and,
4 Installation
L N
1 2 3
1 2 3
Installation manual
11